EVB8700C SMSC, EVB8700C Datasheet - Page 44

no-image

EVB8700C

Manufacturer Part Number
EVB8700C
Description
BOARD EVAL FOR LAN8700
Manufacturer
SMSC
Series
flexPWR™r
Datasheet

Specifications of EVB8700C

Main Purpose
Interface, Ethernet PHY
Embedded
No
Utilized Ic / Part
LAN8700
Primary Attributes
Single Chip PHY, 8/15 kV ESD Protection
Secondary Attributes
>150 Meter Cable Drive, HP Auto-MDIX Auto Polarity Correction
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
638-1040
EVB-LAN8700
Revision 2.2 (12-04-09)
ADDRESS
ADDRESS
ADDRESS
16.15:10
17.15:14
6.15:5
16.9:6
16.5:0
17.13
17.12
17.10
17.11
17.9
6.4
6.3
6.2
6.1
6.0
Link Partner Auto-
Parallel Detection
Link Partner Next
Negotiation Able
Next Page Able
Silicon Revision
FARLOOPBACK
Page Received
EDPWRDOWN
LOWSQEN
Page Able
MDPREBP
Reserved
Reserved
Reserved
Reserved
Reserved
NAME
NAME
NAME
Fault
Table 5.36 Register 6 - Auto Negotiation Expansion
Table 5.38 Register 17 - Mode Control/Status
Table 5.37 Register 16 - Silicon Revision
1 = fault detected by parallel detection logic
0 = no fault detected by parallel detection logic
1 = link partner has next page ability
0 = link partner does not have next page ability
1 = local device has next page ability
0 = local device does not have next page ability
1 = new page received
0 = new page not yet received
1 = link partner has auto-negotiation ability
0 = link partner does not have auto-negotiation ability
Four-bit silicon revision identifier.
Write as 0; ignore on read.
Enable the Energy Detect Power-Down mode:
0 = Energy Detect Power-Down is disabled
1 = Energy Detect Power-Down is enabled
Write as 0, ignore on read
The Low_Squelch signal is equal to LOWSQEN AND
EDPWRDOWN.
Low_Squelch = 1 implies a lower threshold
Low_Squelch = 0 implies a higher threshold
Management Data Preamble Bypass:
0 – detect SMI packets with Preamble
1 – detect SMI packets without preamble
Force the module to the FAR Loop Back mode, i.e. all
the received packets are sent back simultaneously (in
100Base-TX only). This bit is only active in RMII
mode. In this mode the user needs to supply a 50MHz
clock to the PHY. This mode works even if MII Isolate
(0.10) is set.
±15kV ESD Protected MII/RMII 10/100 Ethernet Transceiver with HP Auto-MDIX Support and flexPWR
DATASHEET
(more sensitive).
(less sensitive).
DESCRIPTION
DESCRIPTION
DESCRIPTION
44
SMSC LAN8700/LAN8700i
MODE
MODE
MODE
RO/
RO/
RW
RW
RW
RW
RW
RW
RO
RO
RO
RO
RO
RO
RO
LH
LH
®
Technology in a Small Footprint
DEFAULT
DEFAULT
DEFAULT
Datasheet
0001
0
0
0
0
0
0
0
0
0
0
0
0
0
0

Related parts for EVB8700C