CPD250-4530 POWER ONE, CPD250-4530 Datasheet - Page 6

PWR SUP 250W 3.3/5/12/-12V QUAD

CPD250-4530

Manufacturer Part Number
CPD250-4530
Description
PWR SUP 250W 3.3/5/12/-12V QUAD
Manufacturer
POWER ONE
Series
CPDr
Type
Isolatedr
Datasheet

Specifications of CPD250-4530

Output
5V, 3.3V, ±12V
Number Of Outputs
4
Power (watts)
250W
Mounting Type
Compact PCI®
Voltage - Input
36 ~ 75V
Package / Case
Module
1st Output
5 VDC @ 40A
2nd Output
3.3 VDC @ 40A
3rd Output
12 VDC @ 5.5A
4th Output
-12 VDC @ 2A
Size / Dimension
6.40" L x 1.60" W x 5.07" H (162.5mm x 40.6mm x 128.7mm)
Power (watts) - Rated
250W
Efficiency
82.2%
Approvals
CE, CSA, cUL, EN, TUV, UL
Input Voltage
48V
Screening Level
Commercial
Operating Temperature Min Deg. C
-25C
Operating Temperature Max Deg. C
50C
Mounting Style
Desktop
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant, Not Compliant
Other names
179-2264
Input Fuse and Reverse Polarity Protection
A metal oxide varistor (voltage dependent resistor VDR)
together with the input filter form an effective protection
against high input voltage transients, which typically occur
in most installations.
An incorporated fuse protects the converter against further
damage in the case of a failure.
Table 3: Fuse specification
To avoid unwanted power losses, the CPD200/250 models
are not protected against reverse polarity at the input by a
serial diode, but only with an antiparallel diode. In the case
of reversed input voltage, the input fuse will blow; however
no further damage will occur.
The CPD500 models are protected against reverse polarity
by a special circuitry, which generates no losses. The
converter will simply not start-up, but no damage will occur.
The CPA Series converters are designed for AC input and
have a rectifier bridge on the input.
Input Current Limitation
All converters incorporate an active inrush current limiter in
the input circuitry, which reduces the peak inrush current
value by a factor of 10
switching devices from damage.
Input Undervoltage Shutdown
CPD200/250 models start at approx. V
input voltage is applied; at decreasing V
approx. 21 V.
CPD500 models start at V
CPA models exhibit an undervoltage trigger controlling
start-up and shutdown. The threshold is between 80 and 90
VAC. See also Power Fail Signal.
BCD20005-G Rev. AF, 18-Aug-10
Model
CDP200/250
CPA200/250
CPD500
CPA500/550
Note: The fuse is not customer-accessible.
Note: The inrush current limitation is achieved using an
electronic circuitry. For effective limitation the converter
should not be switched on and off more frequently than every
8 seconds.
Note: The input current I
Note: CPA200/250 with version
operated at V
shutdown and will therefore operate with a high input
current at full load.
i
250 V, 12.5 A T Schurter SPT 5x20, 0001.2515
250 V, 5 A T
250 V, 10 A T
Fuse rating
80 V, 25 A F
V
i min
, as these models have no undervoltage
®
i
may exceed I
i
= 35 V and switch off at V
15 to protect connectors and
Reference
Schurter SPT 5x20, 0001.2511
Littlefuse FKS, 166.7000.525
Schurter MXT250, 0034.6925
200 – 550 Watt CompactPCI
V116 should not be
i max
i
i
, they switch off at
= 22 V, when the
, if V
i
V
i min
i
= 33 V.
.
Page 6 of 19
Efficiency
The efficiency is specified in table 1. Its dependence upon
the input voltage V
2b (CPD500 models). The efficiency of CPD200/250
models depends only marginally upon V
Fig. 2a
CPA Series: Efficiency versus input voltage
Fig. 2b
CPD500 Series: Efficiency versus input voltage
86
82
90
78
86
85
84
83
[%]
[%]
0
®
40
AC-DC and DC-DC Converters
50
CPA, CPD Series Data Sheet
i
is shown in fig. 2a (CPA models) and fig.
100
50
150
CPA500/550
CPA200/250
60
200
CPD500
i
.
www.power-one.com
250
70
VAC
V

Related parts for CPD250-4530