S82Y-VS15S Omron, S82Y-VS15S Datasheet - Page 32

no-image

S82Y-VS15S

Manufacturer Part Number
S82Y-VS15S
Description
MOUNTING BRAKT SIDE FOR S8VM 180
Manufacturer
Omron
Series
S8VSr
Datasheets

Specifications of S82Y-VS15S

Accessory Type
Mounting Bracket(s)
For Use With/related Products
S8VS 180W Power Supplies
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
S82YVS15S
* The rated current for output terminals is 10 A per terminal. Be sure
Installation Environment
Operating Life
Ambient Operating and Storage Environments
S8VS-@@@24A@@ Models only
Satisfy the following conditions when storing the Power Supply for
long periods of time to maintain its remaining service life function.
When storing for more than three months, store within an ambient
temperature range of −25 to +30°C and the humidity range of 25% to
70%.
Periodic Check for Models with Indication
Monitor Except 60-W Models
It may take from several years to more than 10 years under general
operating conditions for the power supply to output the maintenance
forecast monitor alarm (S8VS-@@@24A@@). The total run time
monitor (S8VS-@@@24B@@/S8VS-@@@24BE@) may be a similar
number of years as the maintenance forecast monitor according to
some settings. During operation over an extended period of time,
periodically check if the maintenance forecast monitor output (Yrs) or
total run time monitor output (kh) is correctly functioning by the
following procedure.
1. Select the operation mode.
2. Check that the output (Yrs/kh) is turned ON (with continuity).
3. In the operation mode, press and hold the Down Key D (10) and
4. Release keys to return to the regular state.
Note: DC output stays ON during the periodical check.
• Strip I/O wires for 11 mm when using a screwless terminal block.
• Do not use the Power Supply in locations subject to shocks or
• Install the Power Supply well away from any sources of strong,
• The life of a Power Supply is determined by the life of the
• Store the Power Supply at a temperature of −25 to 65°C and a
• Do not use the Power Supply in areas outside the derating curve
• Use the Power Supply at a humidity of 25% to 85%.
• Do not use the Power Supply in locations subject to direct sunlight.
• Do not use locations where liquids, foreign matter, or corrosive
to use multiple terminals simultaneously for current that exceeds
the terminal rating. When applying a current of 10 A or more, use at
least two terminals each for the positive and negative wires.
vibrations. In particular, install the Power Supply as far away as
possible from contactors or other devices that are a vibration
source.
high-frequency noise and surge.
electrolytic capacitors used inside. Here, Arrhenius Law applies,
i.e., the life will be cut in half for each rise of 10°C or the life will be
doubled for each drop of 10°C. The life of the Power Supply can
thus be increased by reducing its internal temperature.
humidity of 25% to 90%.
otherwise, internal parts may occasionally deteriorate or be
damaged.
gases may enter the interior of Products.
the Mode Key M (8) simultaneously for at least three seconds.
The main display (6) changes to “
An inactive output (Yrs/kh) (no continuity) in the “
indicates the correct function.
a02
.”
a02
” indication
Overcurrent Protection
Alarm Output for Models with Indication Monitor
Except 60-W and BE Models
When using the alarm output, sufficiently consider the maximum
ratings, residual voltage, and leakage current.
Transistor output:
30 VDC max., 50 mA max.
ON residually voltage:2 V max.
OFF leakage current: 0.1 mA max.
Dielectric Strength Test
If a high voltage is applied between an input and the case (FG), it will
pass though the LC of the built-in noise filter and energy will be stored.
If the high voltages used for dielectric strength testing are turned ON
and OFF with a switch, timer, or similar device, impulse voltage will
be generated when the voltage is turned OFF and internal parts may
possibly be damaged. To prevent the generation of impulse voltages,
reduce the applied voltage slowly with a variable resistor on the test
device or turn the voltage ON and OFF at the zero-cross point.
Inrush Current
When two or more Power Supplies are connected to the same input,
the total current is the sum of the currents for each Supply. Select
fuses and circuit breakers giving sufficient consideration to the fusing
or operating characteristics so that fuses will not burn and breakers
will not break due to inrush current.
• Internal parts may possibly deteriorate or be damaged if a
• Internal parts may possibly deteriorate or be damaged if the Power
480-W Models
60-, 90-, 120-,
180-, 240-W
Models
short-circuited or overcurrent state continues during operation.
Supply is used for applications with frequent inrush current or
overloading at the load end. Do not use the Power Supply for such
applications.
(Yrs/kh)
(DC LOW)
16
15
10
10
models
1
6
12
Sinking for S8VS-24A@/@@@24B@ models
Sourcing for S8VS-@@@24AP@/@@@24BP@
Sinking/Sourcing for S8VS-48024A/B models
9
11
1
(Yrs/kh)
14
(COMMON)
13
12
13
11
(DC LOW)
2
3
3
2
7
8
9
4
5
S8VS
6
7
8
4
5
32

Related parts for S82Y-VS15S