LS75-36 TDK Corporation, LS75-36 Datasheet - Page 5

POWER SUPPLY 36V 2.1A SGL OUTPUT

LS75-36

Manufacturer Part Number
LS75-36
Description
POWER SUPPLY 36V 2.1A SGL OUTPUT
Manufacturer
TDK Corporation
Series
LSr
Type
Industrialr
Datasheets

Specifications of LS75-36

Number Of Outputs
1
Efficiency
86%
Voltage - Output
36V
Power (watts)
75W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
88 ~ 264VAC
Mounting Type
Chassis Mount
1st Output
36 VDC @ 2.1A
Size / Dimension
5.1" L x 3.8" W x 1.5" H (129.5mm x 96.5mm x 38.1mm)
Power (watts) - Rated
75.6W
Operating Temperature
-25°C ~ 70°C
Approvals
CE, EN, IEC, UL
Output Current (max)
2.1A
Input Frequency
47 to 63Hz
Screening Level
Commercial
Product Height (mm)
38.1mm
Operating Temperature Min Deg. C
-25C
Operating Temperature Max Deg. C
70C
Mounting Style
Chassis
Pin Count
5
Brand/series
LS Series
Configuration
Enclosed
Current, Output
2.1
Frequency, Input
47-63 Hz
Height
1.5 Inch
Length
5.1 Inch
Line Regulation
144 mV
Load Regulation
288 mV
Operation
Switching
Output
36 VDC @ 2.1 A
Power Rating
76 Watts
Power, Output
75.6 W
Primary Type
AC-DC
Ripple, Rejection
150 mV
Temperature, Operating
–25 to 70 degree C
Temperature, Storage
–40 to 85 degree C
Voltage, Adjustment Range
32.00-40.00
Voltage, Input
88 to 264/125 to 373 VAC/VDC
Voltage, Output
36 VDC
Weight
14.7 Ozs.
Width
3.8 Inch
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
RoHS Compliant part
Other names
285-1829
LS7536

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LS75-36
Manufacturer:
TDK-LAMBDA
Quantity:
617
4. Isolation / Withstand Voltage
4-1. Isolation Test
Isolation resistance between output and FG (chassis) shall be more than 100MΩ at 500VDC. For safety, voltage setting
of DC isolation tester must be done before the test. Ensure that the unit is fully discharged after the test.
4-2. Withstand Voltage
This series is designed to withstand 3.0kVAC between input and output, 1.5kVAC between input and FG (chassis) and
500VAC between output and FG (chassis) each for 1 minute. When testing withstand voltage, set current limit of with-
stand voltage test equipment at 20mA ( Output-FG (chassis) : 100mA ). The applied voltage must be gradually increased
from zero to testing value and then gradually decreased for shut down. When timer is used, the power supply may be
damaged by high impulse voltage at timer switch on and off. Connect input and output as follows :
(a) Input ~ FG (chassis) : solid line
(b) Input ~ Output : dotted line
1.5kVAC, 1min (20mA)
3kVAC, 1min ( 20mA )
(a) Output ~ FG (chassis) : 500VDC, 100MΩ or more
Isolation
Tester
Withstand
Voltage
Tester
AC(L)
AC(N)
FG
AC(L)
AC(N)
FG
+ V
- V
+V
- V
+V
+V
-V
-V
4
Withstand
Voltage
Tester
(c) Output ~ FG (chassis) : 500VAC, 1min (100mA)
FG
AC(L)
AC(N)
LS