AXB050X43-SRZ Lineage Power, AXB050X43-SRZ Datasheet - Page 11

CONVERTER DC/DC 5-15V 50W SMD

AXB050X43-SRZ

Manufacturer Part Number
AXB050X43-SRZ
Description
CONVERTER DC/DC 5-15V 50W SMD
Manufacturer
Lineage Power
Series
Austin Lynx™r
Type
Point of Load (POL) Non-Isolated with Remote On/Offr
Datasheet

Specifications of AXB050X43-SRZ

Output
5 ~ 15V
Number Of Outputs
1
Power (watts)
50W
Mounting Type
Surface Mount
Voltage - Input
20 ~ 30V
Package / Case
6-SMD Module
1st Output
5 ~ 15 VDC @ 8A
Size / Dimension
1.30" L x 0.53" W x 0.33" H (33mm x 13.5mm x 8.3mm)
Power (watts) - Rated
50W
Operating Temperature
-40°C ~ 85°C
Efficiency
94%
Approvals
CSA, EN, UL, VDE
Output Power
120 W
Input Voltage Range
20 V to 30 V
Output Voltage (channel 1)
5 V to 15 V
Output Current (channel 1)
8 A
Package / Case Size
SMD
Output Type
Non-Isolated
Output Voltage
5 V to 15 V
Output Current
8A
Input Voltage
24V
Screening Level
Industrial
Product Length (mm)
33mm
Product Depth (mm)
13.46mm
Mounting Style
Surface Mount
Pin Count
6
Product
Non-Isolated / POL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
555-1107-2
CC109104857

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AXB050X43-SRZ
Manufacturer:
LINEAGE
Quantity:
119
Part Number:
AXB050X43-SRZ
Manufacturer:
LINEAGE
Quantity:
20 000
Data Sheet
December 18, 2009
Feature Description
Remote On/Off
The Austin Lynx
On/Off pin for remote On/Off operation. Positive Logic
On/Off signal, device code suffix “4”, turns the module
ON during a logic High on the On/Off pin and turns the
module OFF during a logic Low.
For positive logic modules, the circuit configuration for
using the On/Off pin is shown in Figure 28. The On/Off
pin is an open collector/drain logic input signal (Von/Off)
that is referenced to ground. During a logic-high
(On/Off pin is pulled high internal to the module) when
the transistor Q1 is in the Off state, the power module is
ON. Maximum allowable leakage current of the
transistor when Von/off = V
logic-low when the transistor Q1 is turned-On, the
power module is OFF. During this state VOn/Off must
be less than 1.2V. When not using positive logic On/off
pin, leave the pin unconnected or tie to V
Remote Sense
The Austin Lynx 24V power modules have a Remote
Sense feature to minimize the effects of distribution
losses by regulating the voltage at the Remote Sense
pin (See Figure 29). The voltage between the Sense
pin and Vo pin must not exceed 0.5V.
The amount of power delivered by the module is defined
as the output voltage multiplied by the output current
(Vo x Io). When using Remote Sense, the output
voltage of the module can increase which increases the
power output of the module. Make sure that the
maximum output power of the module remains at or
below the maximum rated power. When the Remote
Sense feature is not being used, connect the Remote
Sense pin to the output of the module.
LINEAGE
Figure 28. Remote On/Off Implementation circuit.
I
ON/OFF
GND
VIN+
ON/OFF
POWER
V
Q1
ON/OFF
+
_
TM
24V SMT power modules feature an
R1
IN,max
R2
R3
R4
is 10µA. Applying a
Q2
18/20– 30/32Vdc input; 3 – 6Vdc & 5 – 15Vdc Output; 30/50W
IN.
MODULE
PWM Enable
Q3
CSS
Austin Lynx
Overcurrent Protection
To provide protection in a fault (output overload)
condition, the unit is equipped with internal
current-limiting circuitry and can endure current limiting
continuously. At the point of current-limit inception, the
unit enters hiccup mode. The unit operates normally
once the output current is brought back into its specified
range. The average output current during hiccup is 20%
I
Input Undervoltage Lockout
At input voltages below the input undervoltage lockout
limit, the module operation is disabled. The module will
begin to operate at an input voltage above the
undervoltage lockout turn-on threshold.
Overtemperature Protection
To provide protection in a fault condition, the unit is
equipped with a thermal shutdown circuit. The unit will
shutdown if the overtemperature threshold of 130
exceeded at the thermal reference point T
thermal shutdown is not intended as a guarantee that
the unit will survive temperatures beyond its rating.
Once the unit goes into thermal shutdown it will then
wait to cool before attempting to restart.
Output Voltage Programming
The output voltage of the Austin Lynx 24V can be
programmed to any voltage in the specified ranges by
connecting a resistor (shown as Rtrim in Figure 30)
between the Trim and GND pins of the module. Without
an external resistor between the Trim and GND pins,
the output of the module will be at the low-end of the
specified range. To calculate the value of the trim
resistor, Rtrim for a desired output voltage, use the
following equations:
For the AX030A0X modules,
O, max
Figure 29.
Remote Sense operation.
.
R
R
distrib u tio n
distrib u tio n
TM
24V: Non-isolated Power Modules:
Rtrim
R
R
c o nta c t
c o nta c t
Effective Circuit Configuration for
=
Vo
10500
V
C O M
IN
(+ )
. 3
018
S e n se
C O M
V
O
3480
Ω
R
R
ref
c o n ta c t
c o n ta c t
. The
R
R
d istribu tio n
d istribu tio n
o
R
C is
L O A D
11

Related parts for AXB050X43-SRZ