CONVER DC-DC 0.6 3.63V @ 12A SMD

APXH012A0X3-SRZ

Manufacturer Part Number
APXH012A0X3-SRZ
Description
CONVER DC-DC 0.6 3.63V @ 12A SMD
Manufacturer
Lineage Power
Series
Micro TLynx™r
Type
Point of Load (POL) Non-Isolated with Remote On/Offr
Datasheet

Specifications of APXH012A0X3-SRZ

Output
0.6 ~ 3.63V
Number Of Outputs
1
Power (watts)
40W
Mounting Type
Surface Mount
Voltage - Input
2.4 ~ 5.5V
Package / Case
10-SMD Module
1st Output
0.6 ~ 3.63 VDC @ 12A
Size / Dimension
0.80" L x 0.45" W x 0.33" H (20.3mm x 11.4mm x 8.5mm)
Power (watts) - Rated
40W
Operating Temperature
-40°C ~ 85°C
Efficiency
94%
Approvals
CSA, EN, UL, VDE
Output Power
44 W
Input Voltage Range
2.4 V to 5.5 V
Output Voltage (channel 1)
0.6 V to 3.63 V
Output Current (channel 1)
12 A
Package / Case Size
20.3 mm x 11.4 mm x 8.5 mm
Output Type
Non-Isolated
Output Voltage
0.6 V to 3.63 V
Product
Non-Isolated / POL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
555-1149-2
CC109130481
Data Sheet
April 7, 2011
Thermal Considerations
Power modules operate in a variety of thermal
environments; however, sufficient cooling should always
be provided to help ensure reliable operation.
Considerations include ambient temperature, airflow,
module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of
the module will result in an increase in reliability. The
thermal data presented here is based on physical
measurements taken in a wind tunnel. The test set-up
is shown in Figure 45. The preferred airflow direction
for the module is shown in Figure 46.
The thermal reference points, T
specifications are shown in Figure 46. For reliable
operation the temperatures at these points should not
exceed 125
not exceed the rated power of the module (Vo,set x
Io,max).
Please refer to the Application Note “Thermal
Characterization Process For Open-Frame Board-
Mounted Power Modules” for a detailed discussion of
thermal aspects including maximum device
temperatures.
LINEAGE
Wind Tunnel
PWBs
POWER
Figure 45. Thermal Test Setup.
o
C. The output power of the module should
flow
Air
(0.50)
x
12.7_
(3.0)
76.2_
25.4_
(1.0)
2.4 – 5.5Vdc input; 0.6Vdc to 3.63Vdc output; 12A output current
ref
Probe Location
for measuring
airflow and
ambient
temperature
Power Module
used in the
Micro TLynx
Figure 46. Preferred airflow direction and location of
hot-spot of the module (Tref).
TM
: Non-isolated DC-DC Power Modules:
17