APXS002A0X-SRZ Lineage Power, APXS002A0X-SRZ Datasheet - Page 18

PWR MOD DC/DC 0.59-5.5V @ 2A SMD

APXS002A0X-SRZ

Manufacturer Part Number
APXS002A0X-SRZ
Description
PWR MOD DC/DC 0.59-5.5V @ 2A SMD
Manufacturer
Lineage Power
Series
Pico TLynx™r
Type
Point of Load (POL) Non-Isolated with Remote On/Offr
Datasheet

Specifications of APXS002A0X-SRZ

Output
0.6 ~ 5.5V
Number Of Outputs
1
Power (watts)
15W
Mounting Type
Surface Mount
Voltage - Input
3 ~ 14V
Package / Case
10-SMD Module
1st Output
0.6 ~ 5.5 VDC @ 2A
Size / Dimension
0.48" L x 0.48" W x 0.25" H (12.2mm x 12.2mm x 6.3mm)
Power (watts) - Rated
11W
Operating Temperature
-40°C ~ 85°C
Efficiency
93%
Approvals
CSA, EN, UL, VDE
Input Voltage Range
3 V to 14 V
Input Voltage (nominal)
12 V
Output Voltage (channel 1)
0.6 V to 5.5 V
Output Current (channel 1)
2 A
Package / Case Size
12.2 mm x 12.2 mm x 6.25 mm
Output Type
Non-Isolated
Output Voltage
0.6 V to 5.5 V
Product
Non-Isolated / POL
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
555-1160-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
APXS002A0X-SRZ
Manufacturer:
GECRITICALPOWER
Quantity:
20 000
Data Sheet
March 31, 2011
Thermal Considerations
Power modules operate in a variety of thermal
environments; however, sufficient cooling should
always be provided to help ensure reliable operation.
Considerations include ambient temperature, airflow,
module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of
the module will result in an increase in reliability. The
thermal data presented here is based on physical
measurements taken in a wind tunnel. The test set-up
is shown in Figure 59. The preferred airflow direction
for the module is in Figure 60.
The thermal reference points, T
specifications are also shown in Figure 13. For reliable
operation the temperatures at these points should not
exceed 140
not exceed the rated power of the module (Vo,set x
Io,max).
Please refer to the Application Note “Thermal
Characterization Process For Open-Frame Board-
Mounted Power Modules” for a detailed discussion of
thermal aspects including maximum device
temperatures.
LINEAGE
Wind Tunnel
PWBs
POWER
Figure 59. Thermal Test Setup.
o
C. The output power of the module should
flow
Air
(0.50)
x
12.7_
(3.0)
76.2_
25.4_
(1.0)
ref
3 – 14Vdc input; 0.6Vdc to 5.5Vdc output; 2A output current
Probe Location
for measuring
airflow and
ambient
temperature
Power Module
12V Pico TLynx
used in the
TM
Figure 60. Preferred airflow direction and location
of hot-spot of the module (Tref).
2A: Non-isolated DC-DC Power Modules
18

Related parts for APXS002A0X-SRZ