EHD-RD3306 Panasonic - ECG, EHD-RD3306 Datasheet - Page 2

CONVERTER DC/DC -5.1V OUT -30MA

EHD-RD3306

Manufacturer Part Number
EHD-RD3306
Description
CONVERTER DC/DC -5.1V OUT -30MA
Manufacturer
Panasonic - ECG
Series
EHD-RDr
Type
Point of Load (POL) Non-Isolatedr
Datasheet

Specifications of EHD-RD3306

Output
-5.1V
Number Of Outputs
1
Power (watts)
1W
Mounting Type
Through Hole, Right Angle
Voltage - Input
-113 ~ -170V
Package / Case
6-SIP Module (4 Leads)
1st Output
-5.1 VDC @ 30mA
Size / Dimension
0.75" L x 0.59" W x 0.28" H (19mm x 15mm x 7mm)
Power (watts) - Rated
0.1W
Operating Temperature
-25°C ~ 85°C
Efficiency
46%
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
Other names
EHDRD3306
P11455
Part Name
Vin
[Absolute Maximum Ratings]
[Electric Characteristics]
[Test Circuit]
No.
No.
1
2
3
1
2
3
4
5
6
7
note1:Please refer to the derating curve for maximum output current.
note2:The output ripple doesn't include the spike noise.
note3 : Avoid dew condensation always.
DC-DC Converter
Operational Temperature
Storage Temperature
Output ripple voltage
Input voltage range
Load regulation
Output voltage
Line regulation
Output current
Power Supply
Efficiency
Item
Item
IN
1
+
Panasonic Electronic Devices Co.,Ltd.
Symbol
Symbol
Topr
Vout
Tstg
Iout
Vin
Vin
33μF
Vp
Vr
Vl
η
/200V
We recommend Low Impedance Aluminium capacitors for power supply.
-4.75
-113
Min.
-25  to  +105
35
-25  to  +85
EHDRD3306
Part No.
Specification
Rating
-170
GND
4
-5.10
-141
Typ.
0.02
0.01
0.02
46
EHDRD3306
-5.35
Max.
-170
0.15
0.15
0.15
-30
TP
5
degC
degC
VDC
Unit
VDC
VDC
VDC
VDC
Vp-p
Unit
OUT
mA
6
%
+
100μF
Refer to derating curve.
Avoid dew condensation
(note3)
Ambient Temperature:25 degC
Vin=-141VDC
Iout=-100mA
Vin=-141 to -170VDC
Vin=-113 to -170VDC
Iout=-30mA
Vin=-141VDC
Iout=0 to -30mA
Vin=-141VDC
Iout=-30mA (note2)
Vin=-141VDC
Iout=-30mA
/25V
Condition/notes
Remarks
Iout
3 - 2
Vout
(note1)
Load

Related parts for EHD-RD3306