MW010A Lineage Power, MW010A Datasheet

no-image

MW010A

Manufacturer Part Number
MW010A
Description
CONVERTER DC/DC 5V 10W OUT
Manufacturer
Lineage Power
Series
MW010r
Type
Isolatedr
Datasheet

Specifications of MW010A

Output
5V
Number Of Outputs
1
Power (watts)
10W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
4-DIP Module
1st Output
5 VDC @ 2A
Size / Dimension
2.00" L x 1.60" W x 0.50" H (50.8mm x 40.6mm x 12.7mm)
Power (watts) - Rated
10W
Operating Temperature
-40°C ~ 85°C
Efficiency
80%
Approvals
CE, CSA, UL, VDE
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MW010A1
Manufacturer:
ROCKWELL
Quantity:
1 920
Part Number:
MW010A1
Manufacturer:
LUCENT
Quantity:
20 000
Data Sheet
April 2008
The MW010-Series Power Modules are encapsulated in non-
conductive cases measuring 50.8 mm long, 40.6 mm wide,
and 12.7 mm high (2.00 in. x 1.60 in. x 0.50 in.)
Features
n
n
n
n
n
n
n
n
n
n
n
n
n
n
Small size: 50.8 mm x 40.6 mm x 12.7 mm
(2.00 in. x 1.60 in. x 0.50 in.)
Wide input voltage range: 36 Vdc to 75 Vdc
Output current limiting, unlimited duration
Output overvoltage clamp
Load regulation: 0.15% max. (MW010A, B, C)
Line regulation: 0.10% max. (MW010A, B, C)
Input undervoltage lockout
Input-to-output isolation
No external filtering required
Operating ambient temperature range:
–40 °C to +85 °C
Meets FCC Class A requirements for radiated
emissions
High reliability
UL* Recognized, CSA
VDE Licensed
CE mark meets 73/23/EEC and 93/68/EEC
directives
Certified, and
.
Applications
n
n
n
Options
n
n
Description
The MW010A, B, C, BK, and CL Power Modules are
dc-dc converters that operate over an input voltage
range of 36þVdc to 75þVdc and provide precisely
regulated dc outputs. The outputs are fully isolated
from the inputs, allowing versatile polarity configura-
tions and grounding connections. The modules have
maximum power ratings of 10 W at a typical full-load
efficiency of 83% (80% for the MW010A).
The modules are encapsulated in nonconductive
cases that mount on PC boards. In a natural convec-
tion environment, the modules are rated to full load at
85 °C with no heat sinking or external filtering.
For applications requiring remote on/off, the
MW010A1, B1, C1, BK1, and CL1 Power Modules
are available. These modules are equivalent to the
previously described modules, except for the addition
of the remote on/off and associated terminal.
* UL is a registered trademark of Underwriters Laboratories, Inc.
† CSA is a registered trademark of Canadian Standards Associa-
‡ This product is intended for integration into end-use equipment.
MW010-Series Power Modules:
tion.
All the required procedures for CE marking of end-use equip-
ment should be followed. (The CE mark is placed on selected
products.)
36 Vdc to 75 Vdc Inputs; 10 W
Telecommunications
Distributed power architecture
Electronic data processing
Remote on/off
Standard long pin: 5.8 mm ± 0.5 mm
(0.230 in. ± 0.020 in.)

Related parts for MW010A

MW010A Summary of contents

Page 1

... Standard long pin: 5.8 mm ± 0 (0.230 in. ± 0.020 in.) . Description The MW010A BK, and CL Power Modules are dc-dc converters that operate over an input voltage range of 36þVdc to 75þVdc and provide precisely regulated dc outputs. The outputs are fully isolated from the inputs, allowing versatile polarity configura- tions and grounding connections ...

Page 2

... Min V — — I, trans — — T – –40 stg Symbol Min — I, max — — — — — April 2008 Max Unit 80 V 100 V 500 V 85 °C 100 °C Typ Max Unit — 625 mA 2 0.3 1 — mAp-p 50 — dB Lineage Power ...

Page 3

... V O, set MW010B V O, set MW010C V O, set MW010BK V O1, set V O2, set MW010CL V O1, set V O2, set MW010A — MW010A — MW010A — MW010B — MW010C — MW010A — MW010B, C — MW010BK, CL — MW010A — MW010B, C — MW010BK, CL — MW010A ...

Page 4

... O O, max Weight 4 (continued) Device MW010A MW010B, C MW010BK, CL MW010A MW010B °C; MW010A A MW010B max MW010A MW010B, C, BK, CL All O, max MW010A MW010B, C, BK, CL All Min — 10 Min ); °C) A — April 2008 Symbol Min Typ Max — — — 6.3 — ...

Page 5

... Module On Module Off Output Overvoltage Clamp Lineage Power Device Symbol (–) I All I on/off All V on/off All V on/off All I on/off All V on/off MW010A — MW010BK, CL — All V UVLO All V UVLO MW010A V O, clamp MW010B V O, clamp MW010C V O, clamp MW010BK V O1, clamp V ...

Page 6

... OUTPUT CURRENT ( Regulation ° set max ) O, set ) O, set set typ V O, set ) O, set set min ) O, set O, set) –50 – OPERATING AMBIENT TEMPERATURE, T Operating Ambient Temperature Range 0 max I 0.30 0.35 8-641(C) 100 125 ( C) A 8-642(C) Lineage Power ...

Page 7

... O Figure 7. MW010BK, CL Typical Output 8-643( 1.2 1.4 1.6 1.8 2.0 (A) O 8-644(C) Figure 8. MW010A Typical Converter = 25 °C A MW010-Series Power Modules: 36 Vdc to 75 Vdc Inputs 0.2 0.4 0.6 0.8 1.0 1.2 OUTPUT CURRENT Characteristic with One Output Fixed at Full Load °C ...

Page 8

... OUTPUT POWER, P Figure 9. MW010BK, CL Typical Converter Efficiency as a Function of Output Power ° 5 A/10 µs 1.0 A 0.5 A TIME, t (0.5 ms/div) Figure 10. MW010A Typical Output Voltage Waveform for a Step Load Change from 50 max 0.624 A CL 0.416 (W) O Figure 11. MW010B Typical Output Voltage 8-647(C) 15 ...

Page 9

... Figure 15. MW010C Typical Output Voltage = ° set 0 set 0.5 ms 8-520(C) Figure 16. MW010A Typical Output Voltage Start- ° MW010-Series Power Modules: 36 Vdc to 75 Vdc Inputs 100 A/10 µs t 0.2 A 0.5 ms TIME, t (0.5 ms/div) Waveform for a Step Load Change from 50 max ...

Page 10

... TIME ms/div) Figure 17. MW010B, C Typical Output Voltage Start- Up Waveform with Remote On/Off 0 max set 0 set Figure 18. MW010BK, CL Typical Output Voltage Start-Up Waveform with Remote On/Off; 8-649( °C A Data Sheet April 2008 A/10 µ TIME ms/div °C O, max I A Lineage Power 8-650(C) ...

Page 11

... Kelvin connections at module terminals to avoid measurement errors due to socket contact resistance. V (–) I 8-489(C) offsets possible S Figure 21. MW010A Output Voltage and SUPPLY RESISTIVE SCOPE LOAD 8-513(C) Note: All measurements are taken at the module terminals. When socketing, place Kelvin connections at module terminals to avoid measurement errors due to socket contact resistance ...

Page 12

... Top view COMMON V (+) V (– CONNECTION POINT + V on/off I on/off – Figure 23. Remote On/Off Wiring Configuration Data Sheet April 2008 generated by on/off = µA. (–) pin must be I – ON/OFF 8-598(C) Lineage Power ...

Page 13

... If the input meets extra-low voltage (ELV) require- ments, then the converter’s output is considered ELV. The input to these units provided with a maxi- mum 5 A normal-blow fuse in the ungrounded lead. Lineage Power 36 Vdc to 75 Vdc Inputs Design Considerations Input Filtering An internal aluminum electrolytic capacitor is used for filtering ...

Page 14

... Vdc to 75 Vdc Inputs Outline Diagrams Dimensions are in millimeters and (inches). Tolerances, unless otherwise indicated: x.x ± 0.5 mm (0.02 in.), x.xx ± 0.25 mm (0.010 in.) Single-Output Module (MW010A Top View Side View Bottom View 14 April 2008 8-515(C).a Lineage Power ...

Page 15

... April 2008 Outline Diagrams (continued) Dimensions are in millimeters and (inches). Tolerances, unless otherwise indicated: x.x ± 0.5 mm (0.02 in.), x.xx ± 0.25 mm (0.010 in.) Single-Output Module with Remote On/Off (MW010A1, B1, C1) Top View Side View Bottom View Lineage Power 36 Vdc to 75 Vdc Inputs 8-522(C) ...

Page 16

... Vdc to 75 Vdc Inputs Outline Diagrams (continued) Dimensions are in millimeters and (inches). Tolerances, unless otherwise indicated: x.x ± 0.5 mm (0.02 in.), x.xx ± 0.25 mm (0.010 in.) Dual-Output Module (MW010BK, CL) Top View Side View Bottom View 16 April 2008 8-589(C).a Lineage Power ...

Page 17

... Outline Diagrams (continued) Dimensions are in millimeters and (inches). Tolerances, unless otherwise indicated: x.x ± 0.5 mm (0.02 in.), x.xx ± 0.25 mm (0.010 in.) Dual-Output Module with Remote On/Off (MW010BK1, CL1) Top View Side View Bottom View Lineage Power 36 Vdc to 75 Vdc Inputs 8-588(C).a 17 ...

Page 18

... Vdc to 75 Vdc Inputs Recommended Hole Patterns Dimensions are in millimeters and (inches). Single-Output Module (MW010A MODULE OUTLINE 25.4 (1.00) Single-Output Module with Remote On/Off (MW010A1, B1, C1) 18 20.32 (0.800) 7.62 (0.300) 5.08 (0.200) 22.9 (0.90) 20.32 (0.800) 25.4 (1.00) 5.08 (0.200) 5.08 (0.200) 7 ...

Page 19

... April 2008 Recommended Hole Patterns Dimensions are in millimeters and (inches). Dual-Output Module (MW010BK, CL) Dual-Output Module with Remote On/Off (MW010BK1, CL1) Lineage Power (continued) MODULE OUTLINE 20.32 (0.800) 25.4 (1.00) 2.54 (0.100) 5.08 (0.200) 7.62 (0.300) 22.9 (0.90) MODULE OUTLINE 20.32 (0.800) 25 ...

Page 20

... MW010BK +15.0, –15.0 MW010CL Device Code Suffix 1 –SLP A sia-Pacific Head qu art ers T el: + 4283 dle-East an d Afric arters T el: + 6089 286 Ind ia Head qu arters T el: + 28411633 Comcode MW010A 106233950 MW010B 106233976 MW010C 106233992 106467293 106467327 April 2008 ...

Related keywords