JAW050F1 Lineage Power, JAW050F1 Datasheet - Page 9

no-image

JAW050F1

Manufacturer Part Number
JAW050F1
Description
CONVERTER DC/DC 3.3V 33W OUT
Manufacturer
Lineage Power
Series
JAWr
Type
Isolated with Remote On/Offr
Datasheet

Specifications of JAW050F1

Output
3.3V
Number Of Outputs
1
Power (watts)
33W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
9-DIP Module
1st Output
3.3 VDC @ 10A
Size / Dimension
2.40" L x 2.28" W x 0.50" H (61mm x 57.9mm x 12.7mm)
Power (watts) - Rated
33W
Operating Temperature
-40°C ~ 100°C
Efficiency
79%
Approvals
CE, CSA, UL, VDE
Product
Isolated
Output Power
33 W
Input Voltage Range
36 V to 75 V
Input Voltage (nominal)
48 V
Output Voltage (channel 1)
3.3 V
Output Current (channel 1)
10 A
Isolation Voltage
1.5 KV
Package / Case Size
DIP
Output Type
Isolated
Output Voltage
3.3 V
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
JAW050F1
Manufacturer:
LUCENT
Quantity:
560
April 2008
Feature Descriptions
Remote On/Off
Remote Sense
Remote sense minimizes the effects of distribution
losses by regulating the voltage at the remote-sense
connections. The voltage between the remote-sense
pins and the output terminals must not exceed the out-
put voltage sense range given in the Feature Specifica-
tions table, i.e.:
The voltage between the V
must not exceed the minimum output overvoltage pro-
tection voltage as indicated in the Feature Specifica-
tions table. This limit includes any increase in voltage
due to remote-sense compensation and output voltage
set-point adjustment (trim). See Figure 15.
If not using the remote-sense feature to regulate the
output at the point of load, then connect SENSE(+) to
V
Although the output voltage can be increased by both
the remote sense and by the trim, the maximum
increase for the output voltage is not the sum of both.
The maximum increase is the larger of either the
remote sense or the trim. Consult the factory if you
need to increase the output voltage more than the
above limitation.
The amount of power delivered by the module is
defined as the voltage at the output terminals multiplied
by the output current. When using remote-sense and
trim, the output voltage of the module can be
increased, which at the same output current would
increase the power output of the module. Care should
be taken to ensure that the maximum output power of
the module remains at or below the maximum rated
power.
Lineage Power
O
(+) and SENSE(–) to V
[V
O
Figure 14. Remote On/Off Implementation
(+) – V
V
I
on/off
on/off
+
O
(–)] – [SENSE(+) – SENSE(–)] ≤ 0.5 V
ON/OFF
V
V
I
I
(+)
(–)
(continued)
O
O
(–) at the module.
(+) and V
SENSE(+)
SENSE(–)
(continued)
V
V
O
O
(+)
(–)
O
(–) terminals
36 Vdc to 75 Vdc Input, 3.3 Vdc Output; 33 W to 50 W
LOAD
8-720 (F).c
Figure 15. Effective Circuit Configuration for
Output Voltage Set-Point Adjustment
(Trim)
Output voltage trim allows the user to increase or
decrease the output voltage set point of a module. This
is accomplished by connecting an external resistor
between the TRIM pin and either the SENSE(+) or
SENSE(–) pins. The trim resistor should be positioned
close to the module.
If not using the trim feature, leave the TRIM pin open.
With an external resistor between the TRIM and
SENSE(–) pins (R
(V
tion determines the required external-resistor value to
obtain a percentage output voltage change of Δ%.
With an external resistor connected between the TRIM
and SENSE(+) pins (R
point (V
The following equation determines the required exter-
nal-resistor value to obtain a percentage output voltage
change of Δ%.
The voltage between the V
must not exceed the minimum output overvoltage pro-
tection voltage as indicated in the Feature Specifica-
tions table. This limit includes any increase in voltage
due to remote-sense compensation and output voltage
set-point adjustment (trim). See Figure 15.
R
O, adj
R
adj-up
adj-down
SUPPLY
RESISTANCE
) decreases (see Figure 16). The following equa-
CONTACT
O, adj
=
Single-Module Remote-Sense Operation
=
) increases (see Figure 17).
(
------------------------------------------------------------------------- - 1000
V
I
I
1000
------------ - 11
O nom
Δ%
,
adj-down
V
V
I
I
)
(+)
(–)
(
1.225Δ%
adj-up
1
SENSE(+)
SENSE(–)
), the output voltage set point
⎞ kΩ
+
O
V
), the output voltage set
V
------- -
100
Δ%
O
(+) and V
O
(+)
(–)
)
DISTRIBUTION LOSSES
1.225
I
O
O
CONTACT AND
(–) terminals
LOAD
8-651 (F).m
11
9