BXB50-48S05FLT Emerson Network Power, BXB50-48S05FLT Datasheet - Page 2

no-image

BXB50-48S05FLT

Manufacturer Part Number
BXB50-48S05FLT
Description
CONV DC/DC 5V OUT 50W ACTIVE LO
Manufacturer
Emerson Network Power
Series
BXB50r
Type
Isolated with UVLOr
Datasheets

Specifications of BXB50-48S05FLT

Rohs Status
RoHS non-compliant
Output
5V
Number Of Outputs
1
Power (watts)
50W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
9-DIP Module
1st Output
5 VDC @ 10A
Size / Dimension
2.40" L x 2.28" W x 0.50" H (61mm x 57.9mm x 12.7mm)
Power (watts) - Rated
50W
Operating Temperature
-40°C ~ 100°C
Efficiency
82%
Approvals
CSA, EN, UL, VDE
Output Current
10A
Input Voltage
48V
Output Voltage
5V
Output Power
50
Screening Level
Industrial
Operating Temperature Min Deg. C
-40C
Operating Temperature Max Deg. C
100C
Product Height (mm)
12.7mm
Mounting Style
Through Hole
Pin Count
9
Lead Free Status / RoHS Status
Not Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / RoHS Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
BXB50-48S05FLT
Manufacturer:
ARTESYN
Quantity:
560
Part Number:
BXB50-48S05FLT
Quantity:
50
Notes
1
2
3
4
5
6
7
8
Data Sheet © Artesyn Technologies® 2000
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
International Safety Standard Approvals
NUMBER
OUTPUT
POWER
Measured with 10µF tantalum capacitor and 1µF ceramic capacitor across
output.
di/dt = 0.1A/1µs, Vin = 48VDC, Tc = 25°C, load change = 0.5 lo max. to
0.75 lo max. and 0.75 lo max. to 0.5 lo max.
Units should be characterised within systems. External components
required.
Input fusing is recommended based on surge current and maximum input
current.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
Simulated source impedance of 12
Active high remote on/off option is available (standard product is active
low), designate with the suffix ‘FHT’ e.g. BXB50-48S05FHT. Consult
factory for further details and options.
Start-up into resistive load.
(MAX.)
33W
50W
50W
50W
33W
50W
50W
50W
PIN
1
2
3
4
5
6
7
8
9
PIN CONNECTIONS
VDE0805/EN60950/IEC950 File No. 10401-3336-1095
UL1950 File No. E136005
CSA C22.2 No. 950 File No. LR41062C
18-36VDC
18-36VDC
18-36VDC
18-36VDC
36-75VDC
36-75VDC
36-75VDC
36-75VDC
Remote ON/OFF
VOLTAGE
INPUT
FUNCTION
+ Sense
- Sense
+ Vout
- Vout
+ Vin
Case
- Vin
Trim
14.5VDC
17.5VDC
14.5VDC
17.5VDC
4.3VDC
6.5VDC
4.3VDC
6.5VDC
Please consult our website for the following items:
http://www.artesyn.com
OVP
µ
H. 12
µ
H inductor in series with +Vin.
VOLTAGE
OUTPUT
0.500 (12.69)
3.3V
3.3V
7 x Ø.040 (1.02) 0.002 (0.05)
12V
15V
12V
15V
5V
5V
1.400 (35.56)
0.190 (4.83) 0.010 (0.25)
0.010 (0.25)
1.000 (25.40)
CURRENT
OUTPUT
0.400 (10.16)
(MIN.)
Wide input DC/DC converters
0A
0A
0A
0A
0A
0A
0A
0A
CURRENT
OUTPUT
2.28 (57.91) Max.
(MAX.)
4.16A
3.33A
4.16A
3.33A
10A
10A
10A
10A
(48.26)
1.90
ALL DIMENSIONS IN INCHES (mm)
Tolerance : x.xx
PROTECTION
Short circuit protection
Overvoltage protection
Undervoltage protection
Thermal protection
TELECOM SPECIFICATION
Central office interface A
DC/DC CONVERTERS
Application Note
EFFICIENCY
VIEW SHOWN
x.xxx
PIN SIDE UP
(TYP.)
0.400 (10.16)
76%
81%
83%
83%
77%
82%
84%
84%
by using the method shown below.
EXTERNAL OUTPUT TRIMMING
Output can be externally trimmed
0.02in. (0.51mm)
0.010in. (0.254mm)
0.190 (4.83)
0.700 (17.77)
Simscope™
2 x Ø.080 (2.03)
4 x M3 x 0.5 Through
1.000 (25.40)
±0.05%
±0.05%
±0.05%
±0.05%
±0.05%
±0.05%
±0.05%
±0.05%
33 to 50 Watt
0.010 (0.25)
8
7
6
LINE
DOWN
TRIM
REGULATION
TRIM
1.400 (35.56)
UP
|
0.002 (0.05)
Continuous, automatic recovery
33-50W DC/DC
2.000 (50.80)
±0.10%
±0.10%
±0.10%
±0.10%
±0.10%
±0.10%
±0.10%
±0.10%
LOAD
RT1
RT2
OR
automatic recovery
PAGE 147
BXB50-24S3V3FLT
BXB50-48S3V3FLT
110°C baseplate,
BXB50-24S05FLT
BXB50-24S12FLT
BXB50-24S15FLT
BXB50-48S05FLT
BXB50-48S12FLT
BXB50-48S15FLT
ETS300-132-2
NUMBER
0.200 (5.08) Min.
Length for all Input
and Output Pins
Non-latching
Non-latching
2.40 (60.96)
MODEL
0.500 (12.70)
Max.
(7)
5

Related parts for BXB50-48S05FLT