JAHW050F Lineage Power, JAHW050F Datasheet - Page 3

no-image

JAHW050F

Manufacturer Part Number
JAHW050F
Description
CONVERTER DC/DC 3.3V 33W OUT
Manufacturer
Lineage Power
Series
JAHWr
Type
Isolated with Remote On/Offr
Datasheet

Specifications of JAHW050F

Output
3.3V
Number Of Outputs
1
Power (watts)
33W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
9-DIP Module
1st Output
3.3 VDC @ 10A
Size / Dimension
2.40" L x 2.28" W x 0.50" H (61mm x 57.9mm x 12.7mm)
Power (watts) - Rated
33W
Operating Temperature
-40°C ~ 100°C
Efficiency
88%
Approvals
CE, CSA, UL, VDE
Product
Isolated
Output Power
33 W
Input Voltage Range
36 V to 75 V
Output Voltage (channel 1)
3.3 V
Output Current (channel 1)
10 A
Isolation Voltage
1.5 KV
Package / Case Size
DIP
Output Type
Isolated
Output Voltage
3.3 V
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
JAHW050F
Manufacturer:
TYCO
Quantity:
530
Part Number:
JAHW050F1
Manufacturer:
TYCO
Quantity:
27
Part Number:
JAHW050F1
Manufacturer:
VICOR
Quantity:
560
April 2008
Electrical Specifications
Table 2. Output Specifications
* Stability consideration, (See Design Considerations, Output Capacitance Section)
† These are manufacturing test limits. In some situations, results may differ.
‡ Some characteristic are specified with 10
Table 3. Isolation Specifications
Lineage Power
Output Voltage Set Point
Output Voltage
Output Regulation:
Output Ripple and Noise Voltage
External Load Capacitance
Output Current
Output Current-limit Inception
Output Short-circuit Current (V
Efficiency (V
Switching Frequency
Dynamic Response
Isolation Capacitance
Isolation Resistance
(V
(Over all operating input voltage, static resistive
load, and temperature conditions until end of
life. See Figure 18.)
(See Figure 17.):
(At I
ripple specifications.)
(V
(ΔI
tested with a 10 µF aluminum and a 1.0 µF
tantalum capacitor across the load.):
Line (V
Load (I
Temperature (T
RMS
Peak-to-peak (5 Hz to 20 MHz)
Load Change from I
Load Change from I
I
O
O
= 48 V; I
Peak Deviation
Settling Time (V
Peak Deviation
Settling Time (V
/Δt = 1 A/10 µs, V
O
= 90% of V
< I
O
I
O, min
= 36 V to 75 V)
= I
I
O
= 48 V; I
O, min
, the modules may exceed output
= I
O, nom
O, max
C
Parameter
to I
= –40 °C to +100 °C)
O
O
)
O
O, max
; T
O
O
< 10% of peak deviation)
< 10% of peak deviation)
I
= I
= 48 V, T
= 50% to 75% of I
= 50% to 25% of I
C
Parameter
O, max
= 25 °C)
)
O
; T
= 250 mV)
dc-dc Converters; 36 to 75 Vdc Input, 3.3 Output; 33 W to 66 W
C
(continued)
μ
C
= 25 °C;
F aluminum and 1
= 70 °C)
O, max
O, max
:
:
μ
F ceramic.
JAHW050F
JAHW075F
JAHW100F
JAHW050F
JAHW075F
JAHW100F
JAHW050F
JAHW075F
JAHW100F
Device
All
All
All
All
All
All
All
All
All
All
All
All
All
All
Symbol
V
Min
I
I
I
10
V
O, cli
O, cli
O, cli
O, set
I
I
I
η
η
η
O
O
O
O
3.25
3.20
Min
0.5
0.5
0.5
0
2500
Typ
0.01
0.05
88.6
89.2
Typ
170
340
200
200
3.3
15
12
18
23
88
2
2
Max
Max
3.35
3.40
100
15
20
25
0.1
0.2
50
50
10
15
20
*
%I
%V
%V
mVrms
mVp-p
Unit
%V
%V
pF
Unit
Vdc
Vdc
kHz
mV
µF
O, max
µs
µs
%
%
%
A
A
A
A
A
A
O, set
O, set
O
O
3

Related parts for JAHW050F