CW025ACL-M Lineage Power, CW025ACL-M Datasheet - Page 12

no-image

CW025ACL-M

Manufacturer Part Number
CW025ACL-M
Description
CONV DC/DC +5/+-15V 25W OUT
Manufacturer
Lineage Power
Series
CW025r
Type
Isolated with Remote On/Offr
Datasheet

Specifications of CW025ACL-M

Output
5V, ±15V
Number Of Outputs
3
Power (watts)
25W
Mounting Type
Through Hole
Voltage - Input
36 ~ 75V
Package / Case
10-DIP Module
1st Output
5 VDC @ 5A
2nd Output
15 VDC @ 830mA
3rd Output
-15 VDC @ 830mA
Size / Dimension
2.80" L x 2.40" W x 0.50" H (71.1mm x 61mm x 12.7mm)
Power (watts) - Rated
25W
Operating Temperature
-40°C ~ 100°C
Efficiency
83%
Approvals
CE, CSA, UL, VDE
Product
Isolated
Output Power
25 W
Input Voltage Range
36 V to 75 V
Output Voltage (channel 1)
5 V
Output Current (channel 1)
5 A
Output Voltage (channel 2)
15 V
Output Current (channel 2)
0.83 A
Output Voltage (channel 3)
- 15 V
Output Current (channel 3)
0.83 A
Isolation Voltage
500 V
Package / Case Size
DIP
Output Type
Isolated
Output Voltage
5 V
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
4th Output
-
Lead Free Status / Rohs Status
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CW025ACL-M
Manufacturer:
LUCENT
Quantity:
26
CW025 Triple-Output-Series Power Modules:
12
12
Feature Descriptions
Output Overvoltage Clamp
The output overvoltage clamp consists of control cir-
cuitry, independent of the primary regulation loop, that
monitors the voltage on the output terminals. The con-
trol loop of the clamp has a higher voltage set point
than the primary loop (see Feature Specifications
table). This provides a redundant voltage control that
reduces the risk of output overvoltage.
Current Limit
To provide protection in a fault (output overload) condi-
tion, the unit is equipped with internal current-limiting
circuitry. At the point of current-limit inception, the unit
shifts from voltage control to current control. If the out-
put voltage is pulled very low during a severe fault, the
current-limit circuit can exhibit either foldback or
tailout characteristics (output current decrease or
increase). The unit operates normally once the output
current is brought back into its specified range.
Output Voltage Set-Point Adjustment
The output voltage adjustment feature provides the
capability of increasing or decreasing the output volt-
age set point of a module. When the output voltage
adjustment feature is used, the output voltage set point
of all three outputs is adjusted.
The output voltage adjustment can be accomplished by
using an external resistor connected between the TRIM
pin and either the V
external resistor between the TRIM and common pins
(R
With an external resistor connected between the TRIM
and V
(V
Note: The output voltage adjustment must be 90% or
Note: The output voltage adjustment range must not
36 Vdc to 75 Vdc Input; 25 W
O, adj
adj-up
O1
) decreases.
R
more of the nominal output voltage between the
V
), the output voltage set point (V
exceed 110% of the nominal output voltage
between the V
(+) pins (R
O1
adj-down
R
(+) and common terminals.
adj-up
=
=
adj-down
O1
------------------------------------------------ -
O1
V
(+) or common pins. With an
--------------------------------- -
V
O, adj
(+) and common terminals.
O, adj
V
), the output voltage set point
O, nom
42.35
2.5
V
O, nom
V
O, adj
16.94
O, adj
k
) increases.
k
Remote On/Off
Two remote on/off options are available. Positive logic
remote on/off turns the module on during a logic high
voltage on the REMOTE ON/OFF pin, and off during a
logic low. Negative logic remote on/off, suffix code “1,”
turns the module off during a logic high and on during a
logic low.
To turn the power module on and off, the user must
supply a switch to control the voltage between the
on/off terminal and the V
switch can be an open collector or equivalent (see
Figure 21). A logic low is V
imum I
should maintain a logic-low voltage while sinking 1 mA.
During a logic high, the maximum V
the power module is 10 V. The maximum allowable
leakage current of the switch at V
CAUTION: To avoid damaging the module or exter-
Grounding Considerations
For modules without the isolated case ground pin
option, the case is internally connected to the V
For modules with the isolated case ground pin option,
the V
Figure 21. Remote On/Off Implementation
I
(+) is not connected to the case.
on/off
during a logic low is 1 mA. The switch
nal circuitry, the V
nected to the –48 V source before or
simultaneously to connecting the
ON/OFF pin to the –48 V source (either
directly or through the external on/off
circuitry).
I
on/off
V
on/off
+
I
(–) terminal (V
on/off
REMOTE
ON/OFF
V
V
I (+)
I
(–)
= 0 V to 1.2 V. The max-
I
(–) pin must be con-
on/off
on/off
= 10 V is 50 µA.
on/off
generated by
Data Sheet
April 2008
). The
Lineage Power
I
(+) pin.
8-758(C).a

Related parts for CW025ACL-M