NMK0505SAC Murata Power Solutions Inc, NMK0505SAC Datasheet - Page 2

CONV DC/DC 2W 5VIN 5VOUT SIP

NMK0505SAC

Manufacturer Part Number
NMK0505SAC
Description
CONV DC/DC 2W 5VIN 5VOUT SIP
Manufacturer
Murata Power Solutions Inc
Series
NMKr
Type
Isolatedr
Datasheet

Specifications of NMK0505SAC

Number Of Outputs
1
Output
5V
Power (watts)
2W
Mounting Type
Through Hole
Voltage - Input
4.5 ~ 5.5V
Package / Case
7-SIP Module (4 Leads)
1st Output
5 VDC @ 400mA
Size / Dimension
0.77" L x 0.30" W x 0.40" H (19.6mm x 7.6mm x 10.2mm)
Power (watts) - Rated
2W
Operating Temperature
-40°C ~ 85°C
Efficiency
83%
Approvals
UL
Output Power
2 W
Input Voltage Range
4.5 V to 5.5 V
Input Voltage (nominal)
5 V
Output Voltage (channel 1)
5 V
Output Current (channel 1)
400 mA
Isolation Voltage
3 KV
Package / Case Size
SIP
Output Voltage
5 V
Product
Isolated
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
811-1546-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NMK0505SAC
Manufacturer:
MURATAPS
Quantity:
12 000
Part Number:
NMK0505SAC
Manufacturer:
MURATA/村田
Quantity:
20 000
TEMPERATURE DERATING GRAPH
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specifi ed time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions NMK series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 3kVDC for 1 minute.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
The NMK series has been recognized by Underwriters Laboratory for functional insulation. Both input and output should normally be maintained within SELV limits i.e. less than
42.4V peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation sys-
tem. The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the
barrier must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry
according to safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,
construction and environment. The NMK series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We
therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specifi ed test voltage.
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
The NMK series has been recognised by Underwriters Laboratory (UL) to UL 60950 for functional insulation in a maximum ambient temperature of 85ºC and/or case temperature
limit of 130ºC. Case temperature measured on the face opposite the pins. File number E179522 applies.
The NMK Series of converters are not internally fused so to meet the requirements of UL 60950 an input line fuse should always be used. An anti-surge 2A should be used for
NMK05xxSC/SAC models, and an anti-surge 0.75A should be used for NMK12xxSC/SAC models. All fuses should be UL approved and rated to at least the maximum allowable DC
input voltage.
TEMPERATURE CHARACTERISTICS
Parameter
Specifi cation
Storage
Case Temperature above ambient
Cooling
SAFETY APPROVAL
RoHS COMPLIANT INFORMATION
www.murata-ps.com
0
3
2
1
-40
Safe Operating Area
Ambient Temperature (°C)
0
50
85°C
100
150
Conditions
All output types
5V output types
All other output types
Free air convection
This series is compatible with RoHS soldering systems with a peak wave solder temperature of 300°C for 10 seconds. The pin
termination fi nish on the SIP package type is Tin Plate, Hot Dipped over Matte Tin with Nickel Preplate. The DIP types are Matte
Tin over Nickel Preplate. Both types in this series are backward compatible with Sn/Pb soldering systems.
For further information, please visit www.murata-ps.com/rohs
TOLERANCE ENVELOPE
NMKXXXXSAC
V
5%
NOM
10
25
Output Load Current (%)
50
75
3kVDC Isolated 2W Single & Dual Output DC/DC Converters
100
0%
-4%
2%
Technical enquiries email: mk@murata-ps.com, tel:
Min.
-40
-50
NMKXXXXSC
V
5%
NOM
10
25
Output Load Current (%)
Typ.
NMK Series
50
KDC_NMKC.D01 Page 2 of 5
Max.
125
85
28
25
75
+44 (0)1908 615232
100
1%
0%
-3%
Units
°C

Related parts for NMK0505SAC