ACPL-054L-000E Avago Technologies US Inc., ACPL-054L-000E Datasheet - Page 6

ISOLATOR 3.75KVRMS 2CH 8SO

ACPL-054L-000E

Manufacturer Part Number
ACPL-054L-000E
Description
ISOLATOR 3.75KVRMS 2CH 8SO
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of ACPL-054L-000E

Package / Case
SO-8
Voltage - Isolation
3750Vrms
Number Of Channels
2, Unidirectional
Current - Output / Channel
8mA
Data Rate
1MBd
Propagation Delay High - Low @ If
1µs @ 3mA
Current - Dc Forward (if)
20mA
Input Type
DC
Output Type
Open Collector
Mounting Type
Surface Mount
Maximum Forward Diode Current
20 mA
Configuration
2 Channel
Current Transfer Ratio
130 %
Maximum Baud Rate
1 Mbps
Maximum Forward Diode Voltage
1.95 V
Maximum Reverse Diode Voltage
5 V
Maximum Input Diode Current
10 mA
Maximum Power Dissipation
36 mW
Maximum Operating Temperature
+ 105 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
516-2161-5
ACPL-054L

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ACPL-054L-000E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Insulation and Safety Related Specifications
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics* (Option 060)
*
** Refer to the following figure for dependence of P
6
Parameter
Minimum External Air
Gap (Clearance)
Minimum External
Tracking (Creepage)
Minimum Internal
Plastic Gap
(Internal Clearance)
Tracking Resistance
(Comparative Tracking
Index)
Isolation Group
Description
Installation classification per DIN VDE 0110/39, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/39)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
V
Partial discharge < 5 pC
Input to Output Test Voltage, Method a*
V
Partial discharge < 5 pC
Highest Allowable Overvoltage (Transient Overvoltage t
Safety-limiting values – maximum values allowed in the event of a failure.
Insulation Resistance at TS, V
IORM
IORM
Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section,
(IEC/EN/DIN EN 60747-5-5) for a detailed description of Method a and Method b partial discharge test profiles.
for rated mains voltage ≤ 150 V
for rated mains voltage ≤ 300 V
for rated mains voltage ≤ 600 V
for rated mains voltage ≤ 1000 V
Case Temperature
Input Current**
Output Power**
x 1.875 = V
x 1.6 = V
PR
, Type and Sample Test, t
PR
, 100% Production Test with t
Symbol
L(101)
L(102)
CTI
IO
= 500 V
rms
rms
rms
rms
ACPL-M50L
0.08
175
IIIa
5
5
m
= 10 sec,
S
and I
m
= 1 sec,
ACPL-054L
4.9
4.8
0.08
175
IIIa
S
on ambient temperature.
ini
= 60 sec)
ACPL-W50L
ACPL-K54L
8
8
0.08
175
IIIa
Units
mm
mm
mm
Volts
Symbol
V
V
V
V
T
I
P
R
S, INPUT
S
S, OUTPUT
S
IORM
PR
PR
IOTM
Conditions
Measured from input terminals to output
terminals, shortest distance through air.
Measured from input terminals to output
terminals, shortest distance path along
body.
Through insulation distance conductor
to conductor, usually the straight line
distance thickness between the emitter
and detector.
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89,
Table 1)
Characteristic
ACPL-M50L/
054L
I – IV
I – III
I – II
55/105/21
2
560
1063
896
6000
150
150
600
>10
9
ACPL-W50L/
K54L
I – IV
I – IV
I – III
I – III
55/105/21
2
1140
2137
1824
8000
175
230
600
>10
9
Unit
Vpeak
Vpeak
Vpeak
Vpeak
°C
mA
mW
:

Related parts for ACPL-054L-000E