HCPL-314J-500E Avago Technologies US Inc., HCPL-314J-500E Datasheet - Page 3

no-image

HCPL-314J-500E

Manufacturer Part Number
HCPL-314J-500E
Description
OPTOCOUPLER 2CH 0.6A 16-SOIC
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of HCPL-314J-500E

Voltage - Isolation
3750Vrms
Number Of Channels
2, Unidirectional
Propagation Delay High - Low @ If
300ns @ 8mA
Current - Dc Forward (if)
25mA
Input Type
DC
Output Type
Open Collector
Mounting Type
Surface Mount
Package / Case
16-SOIC (0.300", 7.50mm Width)
No. Of Channels
2
Optocoupler Output Type
Gate Drive
Input Current
12mA
Output Voltage
30V
Opto Case Style
SOIC
No. Of Pins
16
Propagation Delay Low-high
0.7µs
Isolation Voltage
3.75kV
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HCPL-314J-500E
Quantity:
2 550
Part Number:
HCPL-314J-500E
Manufacturer:
AGILENT
Quantity:
696
Part Number:
HCPL-314J-500E
Manufacturer:
AVAGO
Quantity:
8 000
Part Number:
HCPL-314J-500E
Manufacturer:
AVAGO原装
Quantity:
20 000
Company:
Part Number:
HCPL-314J-500E
Quantity:
1 700
Recommended Pb-Free IR Profile
Recommended reflow condition as per JEDEC Standard, J-STD-020 (latest revision). Non-Halide Flux should be used.
Regulatory Information
The HCPL-314J has been approved by the following organizations:
IEC/EN/DIN EN 60747-5-2
Approved under:
IEC 60747-5-5:1997 + A1:2002
EN 60747-5-2:2001 + A1:2002
DIN EN 60747-5-2 (VDE 0884
Teil 2):2003-01.
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics
*
** Refer to the following figure for dependence of P
3
Description
Installation classification per DIN VDE 0110/1.89, Table 1
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
Input to Output Test Voltage, Method a*
Highest Allowable Overvoltage
Safety-limiting values
- maximum values allowed in the event of a failure.
Insulation Resistance at T
(Transient Overvoltage t
for rated mains voltage ≤ 1000V
Case Temperature
Input Current**
Output Power**
Refer to the optocoupler section of the Isolation and Control Components Designer’s
Catalog, under Product Safety Regulations section, IEC/EN/DIN EN 60747-5-2, for a detailed
description of Method a and Method b partial discharge test profiles.
V
V
for rated mains voltage ≤ 150 V
for rated mains voltage ≤ 300 V
for rated mains voltage ≤ 600 V
t
t
IORM
m
IORM
m
=1 sec, Partial discharge < 5 pC
=10 sec, Partial discharge < 5 pC
x 1.875=V
x 1.6=V
PR
, Type and Sample Test,
PR
, 100% Production Test with
S
ini
, V
= 60 sec)
IO
= 500 V
rms
rms
rms
rms
S
and I
S
on ambient temperature.
UL
Approval under UL 1577, component recognition pro-
gram up to V
CSA
Approved under CSA Component Acceptance Notice
#5, File CA 88324.
Symbol
V
V
V
T
I
P
R
V
S,INPUT
S
IORM
PR
PR
IOTM
S, OUTPUT
S
ISO
= 5000 V
Characteristic
I - IV
I - IV
I - IV
I - III
55/100/21
2
1230
2306
1968
8000
175
400
1200
>10
9
800
700
600
500
400
300
200
100
0
0
rms
T
25
S
. File E55361.
– CASE TEMPERATURE – °C
50
75 100
Unit
V
V
V
V
°C
mA
mW
Ω
peak
peak
peak
peak
125
P
I
S
150 175
S
(mA)
(mW)
200

Related parts for HCPL-314J-500E