HCPL-3140#500 Avago Technologies US Inc., HCPL-3140#500 Datasheet - Page 7

OPTOCOUPLER 1CH 0.4A 8-SMD

HCPL-3140#500

Manufacturer Part Number
HCPL-3140#500
Description
OPTOCOUPLER 1CH 0.4A 8-SMD
Manufacturer
Avago Technologies US Inc.
Datasheet

Specifications of HCPL-3140#500

Package / Case
8-SMD Gull Wing
Voltage - Isolation
3750Vrms
Number Of Channels
1, Unidirectional
Current - Output / Channel
600mA
Propagation Delay High - Low @ If
300ns @ 8mA
Current - Dc Forward (if)
25mA
Input Type
DC
Output Type
Push-Pull, Totem-Pole
Mounting Type
Surface Mount, Gull Wing
Isolation Voltage
3750 Vrms
Maximum Fall Time
50 ns
Maximum Forward Diode Current
25 mA
Maximum Rise Time
50 ns
Minimum Forward Diode Voltage
1.2 V
Output Device
Logic Gate Photo IC
Configuration
1 Channel
Maximum Forward Diode Voltage
1.8 V
Maximum Reverse Diode Voltage
5 V
Maximum Power Dissipation
250 mW
Maximum Operating Temperature
+ 100 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
HCPL-3140#500HCPL-3140
Manufacturer:
AVAGO
Quantity:
5 000
Company:
Part Number:
HCPL-3140#500HCPL-3140
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Company:
Part Number:
HCPL-3140#500HCPL-3140#300E
Manufacturer:
AVAGO
Quantity:
10 000
Company:
Part Number:
HCPL-3140#500
Manufacturer:
AGERE
Quantity:
24
Company:
Part Number:
HCPL-3140#500
Manufacturer:
AGILENT
Quantity:
20 000
Switching Specifications (AC)
Over recommended operating conditions unless otherwise specified.
Notes:
1. Derate linearly above 70 C free air temperature at a rate of 0.3 mA/ C.
2. Maximum pulse width = 10 s, maximum duty cycle = 0.2%. This value is intended to allow for component tolerances for designs with I
3. Derate linearly above 85 C, free air temperature at the rate of 4.0 mW/ C.
4. Input power dissipation does not require derating.
5. Maximum pulse width = 50 s, maximum duty cycle = 0.5%.
6. In this test, V
7. Maximum pulse width = 1 ms, maximum duty cycle = 20%.
8. In accordance with UL 1577, each optocoupler is proof tested by applying an insulation test voltage 4500 V
9. Device considered a two-terminal device: pins on input side shorted together and pins on output side shorted together.
10. PDD is the difference between t
11. Common mode transient immunity in the high state is the maximum tolerable |dVcm/dt| of the common mode pulse V
12. Common mode transient immunity in a low state is the maximum tolerable |dV
13. This load condition approximates the gate load of a 1200 V/25 A IGBT.
14. The power supply current increases when operating frequency and Qg of the driven IGBT increases.
7
Package Characteristics
Parameter
Propagation Delay Time to
High Output Level
Propagation Delay Time to
Low Output Level
Propagation Delay
Difference Between Any
Two Parts or Channels
Rise Time
Fall Time
Output High Level Common
Mode Transient Immunity
Output Low Level Common
Mode Transient Immunity
Parameter
Input-Output Momentary
Withstand Voltage
Input-Output Resistance
Input-Output Capacitance
minimum = 0.4 A. See Application section for additional details on limiting I
current limit I
60747-5-2 Insulation Characteristics Table, if applicable.
will remain in the high state (i.e. Vo > 6.0 V).
will remain in a low state (i.e. Vo < 1.0 V).
OH
I-O
is measured with a DC load current. When driving capacitive load V
5 A). This test is performed before 100% production test for partial discharge (method B) shown in the IEC/EN/DIN EN
PHL
and t
Symbol
V
R
C
Symbol
t
t
PDD
t
t
|CM
|CM
PLH
PHL
R
F
ISO
I-O
I-O
PLH
H
L
between any two parts or channels under the same test conditions.
|
|
Min.
0.1
0.1
-0.5
25
25
Min.
3750
Typ.
0.2
0.3
50
50
35
35
Typ.
10
0.6
12
OL
peak.
CM
Max.
0.7
0.7
0.5
Max.
/dt| of the common mode pulse, V
OH
will approach V
Units
V
pF
Units
ns
ns
kV/ s
kV/ s
s
s
s
rms
CC
Test
Conditions
Rg = 47 ,
Cg = 3 nF,
f = 10 kHz,
Duty Cycle =
50%,
I
V
T
V
Test
Conditions
T
RH<50% for
V
Freq=1 MHz
F =
as I
CC
A
CM
A
I-O
=25 C,
= 25 C,
8 mA,
rms
= 30 V
=500 V
OH
= 1 kV
approaches zero amps.
for 1 second (leakage detection
CM
CM
, to assure that the output
to assure that the output
Fig.
Fig.
10,11,
12,13,
14,17
18
18
O
Note
8,9
9
peak
Note
14
10
11
12

Related parts for HCPL-3140#500