ADUM3300BRWZ Analog Devices Inc, ADUM3300BRWZ Datasheet - Page 11

no-image

ADUM3300BRWZ

Manufacturer Part Number
ADUM3300BRWZ
Description
IC DIGITAL ISOLATOR 3CH 16-SOIC
Manufacturer
Analog Devices Inc
Series
iCoupler®r
Datasheet

Specifications of ADUM3300BRWZ

Propagation Delay
32ns
Inputs - Side 1/side 2
3/0
Number Of Channels
3
Isolation Rating
2500Vrms
Voltage - Supply
2.7 V ~ 5.5 V
Data Rate
10Mbps
Output Type
Logic
Package / Case
16-SOIC (0.300", 7.5mm Width)
Operating Temperature
-40°C ~ 105°C
No. Of Channels
3
Supply Current
7mA
Supply Voltage Range
2.7V To 5.5V
Digital Ic Case Style
SOIC
No. Of Pins
16
Operating Temperature Range
-40°C To +105°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADUM3300BRWZ
Manufacturer:
ADI
Quantity:
160
Part Number:
ADUM3300BRWZ
Manufacturer:
AD
Quantity:
6 634
Part Number:
ADUM3300BRWZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS
These isolators are suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured by
protective circuits. The asterisk (*) marking on the package denotes DIN V VDE V 0884-10 approval for 560 V peak working voltage.
Table 7.
Description
Installation Classification per DIN VDE 0110
Climatic Classification
Pollution Degree per DIN VDE 0110, Table 1
Maximum Working Insulation Voltage
Input-to-Output Test Voltage, Method B1
Input-to-Output Test Voltage, Method A
Highest Allowable Overvoltage
Safety-Limiting Values
Insulation Resistance at T
Figure 3. Thermal Derating Curve, Dependence of Safety-Limiting Values
For Rated Mains Voltage ≤ 150 V rms
For Rated Mains Voltage ≤ 300 V rms
For Rated Mains Voltage ≤ 400 V rms
After Environmental Tests Subgroup 1
Case Temperature
Side 1 Current
Side 2 Current
After Input and/or Safety Test Subgroup 2
and Subgroup 3
350
300
250
200
150
100
50
0
0
with Case Temperature per DIN V VDE V 0884-10
50
CASE TEMPERATURE (°C)
SIDE #1
S
SIDE #2
100
150
Conditions
V
partial discharge < 5 pC
V
V
Transient overvoltage, t
Maximum value allowed in the event of a failure
(see Figure 3)
V
IORM
IORM
IORM
IO
= 500 V
× 1.875 = V
× 1.6 = V
× 1.2 = V
200
Rev. A | Page 11 of 20
PR
PR
, t
, t
PR
m
m
, 100% production test, t
= 60 sec, partial discharge < 5 pC
= 60 sec, partial discharge < 5 pC
TR
= 10 seconds
RECOMMENDED OPERATING CONDITIONS
Table 8.
Parameter
Operating Temperature
Supply Voltages
Input Signal Rise and Fall Times
1
All voltages are relative to their respective ground. See the DC Correctness
and Magnetic Field Immunity section for information on immunity to external
magnetic fields.
m
1
= 1 sec,
ADuM3300/ADuM3301
Symbol
V
V
V
V
T
I
I
R
S1
S2
S
S
IORM
PR
PR
TR
Symbol
T
V
A
DD1
, V
Characteristic
40/105/21
560
1050
4000
150
265
335
>10
I to IV
I to III
I to II
2
896
672
DD2
9
Min Max
−40 +105 °C
2.7
5.5
1.0
Unit
V peak
V peak
V peak
V peak
V peak
°C
mA
mA
Ω
Unit
V
ms

Related parts for ADUM3300BRWZ