MAX1298CEAE+ Maxim Integrated Products, MAX1298CEAE+ Datasheet - Page 5

IC TEMP SENS W/ADC 16-SSOP

MAX1298CEAE+

Manufacturer Part Number
MAX1298CEAE+
Description
IC TEMP SENS W/ADC 16-SSOP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX1298CEAE+

Function
Temp Monitoring System (Sensor)
Topology
ADC, Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 85°C, External Sensor
Output Type
MICROWIRE™, QSPI™, SPI™
Output Alarm
No
Output Fan
No
Voltage - Supply
4.75 V ~ 5.25 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
16-SSOP
Full Temp Accuracy
+/- 1 C
Digital Output - Bus Interface
Serial (3-Wire)
Digital Output - Number Of Bits
12 bit
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
TIMING CHARACTERISTICS
(V
(MAX1299), f
Note 1: Tested at V
Note 2: Relative accuracy is the deviation of the analog value at any code from its theoretical value after the full-scale range has
Note 3: Conversion time is defined as the number of clock cycles (64 for voltage measurements, 125 for temperature measure-
Note 4: Individual analog input voltages cannot extend beyond the power-supply rails.
Note 5: Input resistance is typically 250MΩ; 5µA limit reflects limitations in production testing.
Note 6: Specifications for full-on status assume continuous conversions. Power modes are software selected (Table 4).
Note 7: Measured at V
Note 8: External load should not change during conversions for specified accuracy.
Note 9: Excludes noise and self-heating effects. Output error for MAX129_C guaranteed by design.
Note 10: External temperature sensing over -40°C to +85°C range, device at +25°C. Guaranteed by design.
SCLK Frequency
SCLK Pulse Width Low
SCLK Pulse Width High
CS Low to SCLK High
SCLK High to CS Setup
CS Pulse Width
SCLK High to CS Low Setup
SCLK High to CS High Setup
DIN Setup to SCLK High Time
DIN Hold Time
SCLK Fall to Output Data Valid
CS Fall to Output Enable
CS Rise to Output Disable
SSTRB Rise to SCLK Rise
SCLK Fall to SSTRB Fall
DD
= +4.75V to 5.25V (MAX1298), V
been calibrated.
ments) multiplied by the internal clock period.
PARAMETER
SCLK
12-Bit Serial-Output Temperature Sensors
= 2.5MHz, T
DD
_______________________________________________________________________________________
FS(+4.75V)
= +5.0V (MAX1298) and V
A
= T
- V
MIN
SYMBOL
FS(+5.25V)
t
DD
f
t
SSTRB
t
SCLK
t
t
t
SCLK
t
CSH
t
t
t
CSS
t
CS0
CS1
t
t
t
to T
CH
DH
DO
CL
CS
DS
DV
TR
= +2.7V to +3.6V (MAX1299), external reference, V
MAX
for the MAX1298 and at V
, unless otherwise noted. Typical values are at T
R
R
R
DD
L
L
L
= 100kΩ, C
= 100kΩ, C
= 100kΩ, C
= +3.0V (MAX1299).
L
L
L
CONDITIONS
= 50pF
= 50pF
= 50pF
FS(+2.7V)
with 5-Channel ADC
- V
FS(+3.6V)
REF
for the MAX1299.
A
= +25°C.) (Figures 4, 6)
= +2.5V (MAX1298), V
MIN
200
200
100
100
100
100
100
50
0
0
TYP
MAX
150
150
200
2.5
50
REF
= +1.2V
UNITS
MHz
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
5

Related parts for MAX1298CEAE+