SA56004ED,118 NXP Semiconductors, SA56004ED,118 Datasheet - Page 14

IC TEMP SENSOR DIGITAL 8SOIC

SA56004ED,118

Manufacturer Part Number
SA56004ED,118
Description
IC TEMP SENSOR DIGITAL 8SOIC
Manufacturer
NXP Semiconductors
Datasheet

Specifications of SA56004ED,118

Package / Case
8-SOIC (3.9mm Width)
Function
Temp Monitoring System (Sensor)
Topology
ADC (Sigma Delta), Multiplexer, Register Bank
Sensor Type
External & Internal
Sensing Temperature
-40°C ~ 125°C, External Sensor
Output Type
I²C™/SMBus™
Output Alarm
Yes
Output Fan
Yes
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Temperature Threshold
+ 150 C
Full Temp Accuracy
+/- 1 C
Digital Output - Bus Interface
I2C
Digital Output - Number Of Bits
11 bit
Supply Voltage (max)
5.5 V
Supply Voltage (min)
3 V
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Supply Current
500 uA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
935274549118
SA56004ED-T
SA56004ED-T
NXP Semiconductors
SA56004X_5
Product data sheet
Status register, at address 02h, during the interrupt service routine and then reset the
ALERT mask bit 7 in the Configuration register to logic 0 at the end of the interrupt service
routine (see
In order for the SA56004X to respond to the ARA command, the bit D0 in the ALERT
mode register must be set LOW.
ALERT mask bit 7 and the ALERT mode bit D0 are both LOW for the POR default.
The following events summarize the ALERT output interrupt operation in the SMBus Alert
mode:
Remark: The bit assignment of the returned data from the ARA reading is listed in
Table
reading will be FFh (1111 1111).
Fig 6.
Event A: Master senses the ALERT line being LOW.
Event A to B: Master sends a read command using the common 7-bit Alert Response
Address (ARA) of 0001100.
Event A to B: Alerting device(s) return ACK signal and their addresses using the
I
master can repeat the alert reading process and work up through all the interrupts).
Event B: Upon the successful completion of returning address, the SA56004X resets its
ALERT output (to OFF) and sets the ALERT mask bit 7 in its configuration register.
Event C: Master should read the device status register to identify and correct the
conditions that caused the Alert interruption. The status register is reset.
Event D: Master resets the ALERT mask bit 7 in the configuration register to enable the
device ALERT output interruption.
2
remote temperature high limit
C-bus Arbitration (the device with the lowest address value sends its address first. The
remote diode temperature
16. If none of the devices on the bus is alerted then the returned data from ARA
ALERT pin in SMBus Alert mode
status register bit 4
Figure
ALERT pin
(RHIGH)
6).
Rev. 05 — 22 May 2008
Digital temperature sensor with overtemperature alarms
A
B
C
D
SA56004X
© NXP B.V. 2008. All rights reserved.
temperature
002aad215
14 of 36

Related parts for SA56004ED,118