MAX5943CEEE+T Maxim Integrated Products, MAX5943CEEE+T Datasheet - Page 9

IC FIREWIRE CURR LIMITER 16-QSOP

MAX5943CEEE+T

Manufacturer Part Number
MAX5943CEEE+T
Description
IC FIREWIRE CURR LIMITER 16-QSOP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX5943CEEE+T

Applications
FireWire® Apps
Fet Type
N-Channel
Number Of Outputs
2
Internal Switch(s)
No
Delay Time - Off
100ns
Voltage - Supply
7.5 V ~ 37 V
Current - Supply
1.3mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
16-QSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Delay Time - On
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
7, 10, 13
PIN
11
12
14
15
16
1
2
3
4
5
6
8
9
OR_ADJ
LATCH
FAULT
GATE2
GATE1
SENSE
NAME
ONQ1
GND
N.C.
OUT
ILIM
TIM
ON
IN
_______________________________________________________________________________________
On/Off-Control Input. ON sets the undervoltage lockout threshold and resets the part after a fault latch.
Drive ON high to enable the device. Drive ON low to disable the device. Connect ON to IN for the default
undervoltage lockout threshold. Connect a resistor-divider from IN to ON and GND to program the desired
undervoltage lockout threshold.
Current-Fault, Active-Low, Open-Drain Output. FAULT asserts and latches low after a current-limit/circuit-
breaker fault has exceeded the current-limit/circuit-breaker timeout period (see the FAULT section).
Current-Limit/Circuit-Breaker Timeout Adjustment Input. Connect TIM to IN for the default timeout period or
connect a resistor from TIM to GND to program the current-limit/circuit-breaker timeout period.
Current-Limit/Circuit-Breaker Threshold Input. Leave ILIM open for a 40mV circuit-breaker threshold,
connect to GND for a 50mV circuit-breaker threshold, or connect to IN for a 60mV circuit-breaker threshold
(see the Current Limiting section).
Latch or Autoretry Fault Management Selection Input. Connect LATCH to IN to select latch-off mode
after a current-limit/circuit-breaker timeout. Connect LATCH to GND for autorestart mode after a current-
limit/circuit-breaker timeout.
ORing Switch Turn-On Current Threshold Adjustment Input. Select one of three ORing switch turn-on
threshold settings: connect OR_ADJ to GND, connect OR_ADJ to IN, or leave OR_ADJ floating (see the
Power-Supply ORing section).
No Connection. Not internally connected.
ORing Switch Manual Turn-On Input. Drive ONQ1 low to enable power-supply ORing. Drive ONQ1 high
to set GATE1 high to allow reverse current flow. ONQ1 is disabled when V
V
Ground
Output Voltage Sense. Connect to the output.
Current-Limiter Switch Gate Drive Output. Connect GATE2 to the gate of the 2nd n-channel MOSFET.
GATE2 is a charge pump with a 45µA pullup current to 5.5V (typ) above OUT when active (see the Typical
Operating Circuit).
ORing Switch Gate-Drive Output. Connect GATE1 to the gate of the 1st n-channel MOSFET. GATE1 is a
charge pump with a 45µA pullup current to 5.5V (typ) above SENSE when active (see the Typical
Operating Circuit).
Current-Sense Negative Input. Connect a current-sense resistor, R
Typical Operating Circuit).
Input Power and Current-Sense Positive Input. Connect IN to the positive terminal of the current-sense
resistor and to the power source (see the Typical Operating Circuit).
FireWire Current Limiter and Low-Drop
ON
is below the V
ON_REF
threshold, and after a current/circuit-breaker fault.
ORing Switch Controller
FUNCTION
SENSE,
from IN to SENSE (see the
IN
is below the UVLO threshold,
Pin Description
9