MCZ33879EK Freescale Semiconductor, MCZ33879EK Datasheet - Page 17

no-image

MCZ33879EK

Manufacturer Part Number
MCZ33879EK
Description
IC SWITCH HI/LO SIDE 16B 32-SOIC
Manufacturer
Freescale Semiconductor
Type
High Side/Low Side Driverr
Datasheet

Specifications of MCZ33879EK

Input Type
SPI
Number Of Outputs
8
On-state Resistance
750 mOhm
Current - Peak Output
1.2A
Voltage - Supply
5.5 V ~ 26.5 V
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
32-SOIC (7.5mm Width) Exposed Pad, 32-eSOIC, 32-HSOIC
Switch Type
High Side/Low Side
Power Switch Family
MCZ33879
Input Voltage
-0.3 to 7V
Power Switch On Resistance
750mOhm
Output Current
600mA
Mounting
Surface Mount
Supply Current
14mA
Package Type
SOIC W EP
Operating Temperature (min)
-40C
Operating Temperature Classification
Automotive
Pin Count
32
Power Dissipation
1.7W
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Output / Channel
-
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MCZ33879EK
Manufacturer:
FREESCALE
Quantity:
20 000
Part Number:
MCZ33879EKR2
Manufacturer:
FREESCALE
Quantity:
1 000
Part Number:
MCZ33879EKR2
Manufacturer:
FREESCALE
Quantity:
1 000
POWER SUPPLY
mode currents. The device may enter Sleep mode via the EN
pin or the V
the current consumed by the V
registers to the Power-ON Reset state. The reset state is
defined as all outputs off and Open Load Detection Current
disabled.
outputs off and apply logic low to the EN input pin or remove
power from the VDD supply pin. Prior to removing V
the device, it is recommended that all control inputs from the
MCU be low.
PARALLELING OF OUTPUTS
the paralleling of outputs for increased current capability.
R
coefficient that provides balanced current sharing between
outputs without destructive operation. This mode of operation
may be desirable in the event the application requires lower
power dissipation or the added capability of switching higher
currents. Performance of parallel operation results in a
corresponding decrease in R
Open Load Detection Currents and the output current limits
increase correspondingly. Paralleling outputs from two or
more different IC devices is possible but not recommended.
FAULT LOGIC OPERATION
over other devices using SPI communications. As command
word one is being written into the shift register, a fault status
word is being simultaneously written out and received by the
MCU. Regardless of the configuration, with no outputs
faulted and Open Load Detection Current enabled, all status
bits being received by the MCU will be zero. When outputs
are faulted (off state open circuit or on state short-circuit /
will be one. The distinction between open circuit fault and
short / over-temperature is completed via the command word.
For example, when a zero command bit is sent and a one
fault is received in the following word, the fault is open / short-
to-battery for high side drive or open / short-to-ground for low
side drive. In the same manner, when a one command bit is
sent and a one fault is received in the following word, the fault
is a short-to-ground / over-temperature for high side drive or
short-to-battery/over-temperature for low side drive. The
timing between two write words must be greater than 300 μs
to allow adequate time to sense and report the proper fault
status.
over-temperature), the status bits being received by the MCU
Analog Integrated Circuit Device Data
Freescale Semiconductor
DS(ON)
The 33879 device has been designed with ultra-low Sleep
Placing the 33879 in Sleep mode resets the internal
To place the 33879 in the Sleep mode, either command all
Using MOSFETs as an output switch conveniently allows
Fault logic of the 33879 device has been greatly simplified
of MOSFETs have an inherent positive temperature
DD
pin. In the Sleep mode (EN or V
DS(ON)
PWR
while the output OFF
pin is less than 5.0 μA.
DD
≤ 0.8 V),
DEVICE OPERATION
DD
from
SPI INTEGRITY CHECK
initial power-up of the V
After initial system start-up or reset, the MCU will write one
32-bit pattern to the 33879. The first 16 bits read by the MCU
will be 8 logic [0]s followed by the fault status of the outputs.
The second 16 bits will be the same bit pattern sent by the
MCU. By the MCU receiving the same bit pattern it sent, bus
integrity is confirmed. Please note the second 16-bit pattern
the MCU sends to the device is the command word and will
be transferred to the outputs with rising edge of
implemented to ensure integrity of SPI communications. SPI
messages consisting of 16 SCLK pulses and multiples of
8 clock pulses thereafter will be acknowledged. SPI
messages consisting of other than 16 + multiples of 8 SCLK
pulses will be ignored by the device.
OVER-TEMPERATURE FAULT
specifically incorporated for each individual output. The
shutdown following an over-temperature condition is
independent of the system clock or any other logic signal.
Each independent output shuts down at 155
When an output shuts down owing to an over-temperature
fault, no other outputs are affected. The MCU recognizes the
fault by a one in the fault status register. After the 33879
device has cooled below the switch point temperature and
15
by the MCU via SPI to shut down.
OVER-VOLTAGE FAULT
device to shut down all outputs until the over-voltage
condition is removed. When the over-voltage condition is
removed, the outputs will resume their previous state. This
device does not detect an over-voltage on the V
over-voltage threshold on the V
V
voltage detection is global, causing all outputs to be turned
OFF.
OUTPUT OFF OPEN LOAD FAULT
reporting of an open load when the corresponding output is
disabled (input bit programmed to a logic low state). The
Output OFF Open Load fault is detected by comparing the
drain-to-source voltage of the specific MOSFET output to an
internally generated reference. Each output has one
dedicated comparator for this purpose.
to-source voltage is less than the output threshold voltage
(V
PWR(OV)
OUT(FLT-TH)
°
Checking the integrity of the SPI communication with the
Important A SCLK pulse count strategy has been
Over-temperature detection and shutdown circuits are
An over-voltage condition on the VPWR pin will cause the
An output OFF open load fault is the detection and
An output OFF open load fault is indicated when the drain-
C hysteresis, the output will activate unless told otherwise
V, with 1.0 V typical hysteresis. A V
) of 2.5 V to 4.0 V. Hence, the 33879 will
DD
and EN pins is recommended.
PWR
FUNCTIONAL DESCRIPTION
pin is specified as
DEVICE OPERATION
°
C to 185
PWR
CS
DD
.
over-
pin. The
°
C.
33879
17

Related parts for MCZ33879EK