BTS5590G Infineon Technologies, BTS5590G Datasheet - Page 5

no-image

BTS5590G

Manufacturer Part Number
BTS5590G
Description
IC LED DRIVER DSO-36
Manufacturer
Infineon Technologies
Datasheets

Specifications of BTS5590G

Topology
PWM, Switched Capacitor (Charge Pump)
Number Of Outputs
5
Internal Driver
Yes
Type - Primary
Automotive
Frequency
1MHz
Voltage - Supply
3.8 V ~ 5.5 V
Mounting Type
Surface Mount
Package / Case
DSO-36
Internal Switch(s)
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage - Output
-
Operating Temperature
-
Current - Output / Channel
-
Efficiency
-
Lead Free Status / Rohs Status
 Details
Other names
BTS5590G
BTS5590GTR
SP000306869

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
BTS5590G
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
BTS5590GX
Manufacturer:
INFINEON
Quantity:
2 155
Part Number:
BTS5590GX
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Part Number:
BTS5590GXUMA1
Manufacturer:
MICRON
Quantity:
1 001
Due to simplification reasons it is also possible to do the double readout of the standard diagnosis all the time. It
is only important to use the data from the second readout in case of PWM-operation with high duty cycles.
Note: In the interest of simplification it could also be possible to use different approaches, e.g.: the setting of the
4
For using the entire diagnosis functionality of the BTS5590G, BTS5576G and BTS5566G during PWM-operation
with high duty cycles a double readout of the standard diagnosis is required.
Summary:
5
More information regarding SPI Power Controllers can be found at
Application Note
Type
BTS5590G, BTS5576G
and BTS5566G
During DC-operation of the channels and PWM-operation with low duty cycles a single readout of the standard
diagnosis is enough to ensure a correct evaluation of the standard diagnosis.
In case of PWM-operation with high duty cycles (
diagnosis is required to ensure a correct reading of the error flags. The double readout of the standard
diagnosis has to be done within the same on-phase (no switch off between the two readouts).
A readout of the standard diagnosis is done with every write command or with the explicit standard diagnosis
read command 01h.
current sense multiplexer is also a write command, which clears the over load flag.
Conclusion
Additional Information
Ordering Code
on request
t
off state application
5
Package
PG-DSO-36-34
http://www.infineon.com/spoc
BTS5590G, BTS5576G, BTS5566G
t
off state_min
) a double readout of the standard
Application Note
1.0, 2008-07-14
Conclusion