SY88702KI TR Micrel Inc, SY88702KI TR Datasheet - Page 3

IC LASR DRVR 622MBPS 5.5V 10MSOP

SY88702KI TR

Manufacturer Part Number
SY88702KI TR
Description
IC LASR DRVR 622MBPS 5.5V 10MSOP
Manufacturer
Micrel Inc
Type
Laser Diode Driver (Fiber Optic)r
Datasheets

Specifications of SY88702KI TR

Number Of Channels
1
Data Rate
622Mbps
Voltage - Supply
4.5 V ~ 5.5 V
Current - Supply
16mA
Current - Modulation
25mA
Operating Temperature
-40°C ~ 85°C
Package / Case
10-TFSOP, 10-MSOP (0.118", 3.00mm Width)
Mounting Type
Surface Mount
Operating Supply Voltage (max)
5.5V
Mounting
Surface Mount
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
SY88702KITR
SY88702KITR
Micrel
SY88702 evaluation board per Figure 2. Ensure proper ESD
precautionary measures are taken before handling sensitive
electronic equipment, including the SY88702 evaluation
board.
hbwhelp@micrel.com or (408) 955-1690
SETUP FOR MEASUREMENTS
This section explains how to connect and setup the
1. Set E3620A to output 5V and then turn off E3620A.
2. Configure Agilent BERT stack:
3. Connect 70843V’s trigger output to 86100A’s trigger
4. Short J1; open J3 on SY88702 evaluation board
5. Connect DIN and /DIN on SY88702 evaluation board
Connect E3620A’s positive lead to GND post and
negative lead to V
a negative supply; ensure that the power supply
polarity is correct.
a) Set the 83752A synthesized sweeper to 622MHz
b) From the 70004A’s pattern menu, choose the
c) From the 70004A’s trigger menu:
d) From the 70004A’s data menu:
input
to 70843V’s data outputs
viii. Crossing = 0
vii. Polarity = NORMAL
PRBS 2
iv. Tracking = ON
vi. Data output = ON
iii. Hi-Level = 0V
v. Attenuation = 0dB
ii. Choose CLK/8 for divider
ii. Amplitude = 800mV (1600mV
i. Choose clock as trigger output
i. External termination = DC termination 0V
31
–1 pattern
EE
post. Note that the board uses
pp
)
3
6. Connect OUT and /OUT on SY88702 evaluation
7. Turn on E3620A. Typical power supply current should
8. Configure 86100A oscilloscope:
board to 86100A’s inputs
be ~53mA, including the SY88702’s current and
current through the on-board 50
termination network. Excessive current usually means
the power supply leads have been connected
backwards. Be careful of this!
a) Verify a trigger signal is present by checking that
b) Press Eye/Mask mode on front panel
c) Choose NRZ eye measurements from on-screen
d) Choose RMS Jitter, Rise Time, Fall Time and Eye
e) Attach 6dB attenuators to oscilloscope’s inputs.
the trigger source button is lit
display
Amplitude measurements from on-screen
selection list
6dB attenuators are required since the scope can
only display 2 V
forms, and the SY88702 evaluation board can
output larger swings than this (25mA
1.25V = 2.5V
ii. Adjust trigger level if necessary
i. Depress this button to choose external source
i. To configure scope to account for
if necessary
external 6dB attenuation, choose Setup
-> Channel X (X = 1 to 4) -> Advanced
-> Attenuator factor = 6dB
pp
pp
)
maximum amplitude wave-
SY88702 Evaluation Board
equivalent
50 =

Related parts for SY88702KI TR