MAX1667EAP+T Maxim Integrated Products, MAX1667EAP+T Datasheet - Page 23

IC SMART BATT CHGR LEVEL2 20SSOP

MAX1667EAP+T

Manufacturer Part Number
MAX1667EAP+T
Description
IC SMART BATT CHGR LEVEL2 20SSOP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of MAX1667EAP+T

Function
Charge Management
Battery Type
All Battery Types
Voltage - Supply
7.5 V ~ 28 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
20-SSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Table 8. ChargerStatus() Bit Descriptions
*Bit position in the D15–D0 data
N/A = Not applicable
CHARGE_INHIBITED
MASTER_MODE
VOLTAGE_NOTREG
CURRENT_NOTREG
LEVEL_2
LEVEL_3
CURRENT_OR
VOLTAGE_OR
THERMISTOR_OR
THERMISTOR_COLD
THERMISTOR_HOT
THERMISTOR_UR
ALARM_INHIBITED
POWER_FAIL
BATTERY_PRESENT
AC_PRESENT
NAME
______________________________________________________________________________________
POSITION
BIT
10
11
12
13
14
15
0
1
2
3
4
5
6
7
8
9
LATCHED?
Yes
N/A
N/A
N/A
Yes
Yes
No
No
No
No
No
No
No
No
No
No
Level 2 Smart Battery Charger
0 = Ready to charge a smart battery
1 = Charger is off; IOUT current = 0mA; DLO = PGND; DHI = LX
Always returns ‘0’
0 = BATT voltage is limited at the voltage set point (BATT = V0).
1 = BATT voltage is less than the voltage set point (BATT < V0).
0 = Current through R1 is at its limit (I
1 = Current through R1 is less than its limit (I
Always returns 1
Always returns 0
0 = ChargingCurrent() value is valid for MAX1667.
1 = ChargingCurrent() value exceeds what MAX1667 can actually deliver.
0 = ChargingVoltage() value is valid for MAX1667.
1 = ChargingVoltage() value exceeds what MAX1667 can actually deliver.
0 = THM voltage < 91% of REF voltage
1 = THM voltage > 91% of REF voltage
0 = THM voltage < 75% of REF voltage
1 = THM voltage > 75% of REF voltage
This bit reports the state of an internal SR flip-flop (denoted THERMISTOR_HOT
flip-flop). The THERMISTOR_HOT flip-flop is set whenever THM is below 23%
of REF. It is cleared whenever BATTERY_PRESENT = 0 or ChargerMode() is
written with POR_RESET = 1.
0 = THM voltage > 5% of REF voltage
1 = THM voltage < 5% of REF voltage
This bit reports the state of an internal SR flip-flop (denoted ALARM_INHIBITED
flip-flop). The ALARM_INHIBITED flip-flop is set whenever the AlarmWarning()
command is written with D15, D14, or D12 set. The ALARM_INHIBITED flip-flop
is cleared whenever BATTERY_PRESENT = 0, or ChargerMode() is written with
POR_RESET = 1, or ChargingVoltage() or ChargingCurrent() is written.
0 = BATT voltage < 89% of DCIN voltage
1 = BATT voltage > 89% of DCIN voltage
0 = No battery is present (THERMISTOR_OR = 1).
1 = A battery is present (THERMISTOR_OR = 0).
0 = VL voltage < 4V
1 = VL voltage > 4V
Chemistry-Independent,
DESCRIPTION
BATT
= I0).
BATT
< I0).
23