MAX3768CUB-T Maxim Integrated, MAX3768CUB-T Datasheet - Page 4

no-image

MAX3768CUB-T

Manufacturer Part Number
MAX3768CUB-T
Description
Limiting Amplifiers 3-5.5V 1.25/2.5Gbps
Manufacturer
Maxim Integrated
Datasheet

Specifications of MAX3768CUB-T

Operating Supply Voltage
5 V
Supply Current
39 mA
Operating Temperature Range
+ 70 C
Package / Case
uMAX EP
Mounting Style
SMD/SMT
Number Of Channels
1
Power Dissipation
1600 mW
+3.0V to +5.5V, 1.25Gbps/2.5Gbps
Limiting Amplifiers
ELECTRICAL CHARACTERISTICS—MAX3265EUE
(Data outputs terminated per Figure 1, V
unless otherwise noted.) (Note 1)
Note 1: Specifications for Input Voltage Range, LOS Assert/Deassert Levels, and CML Output Voltage refer to the total differential
Note 2: Input edge speed is controlled using four-pole, lowpass Bessel filters with bandwidth approximately 75% of the maximum
Note 3: Deterministic jitter is measured with a K28.5 pattern (0011 1110 1011 0000 0101). Deterministic jitter is the peak-to-peak
Note 4: Random jitter is measured with the minimum input signal applied after filtering with a four-pole, lowpass, Bessel filter (fre-
Note 5: Input signal applied after a 933MHz Bessel filter.
Note 6: Input signal applied after a 1.8GHz Bessel filter.
Note 7: Input for LOS assert/deassert and hysteresis tests is a repeating K28.5 pattern. Hysteresis is defined as:
Note 8: Response time to a 10dB change in input power.
4
Data Rate
Input Voltage Range
Deterministic Jitter
Random Jitter
Data Output Edge Speed
LOS Hysteresis
LOS Assert/Deassert Time
Low LOS Assert Level
Low LOS Deassert Level
Medium LOS Assert Level
Medium LOS Deassert Level
High LOS Assert Level
High LOS Deassert Level
Squelch Input Current
Differential Input Resistance
Input-Referred Noise
CML Output Voltage
LOS Output High Voltage
LOS Output Low Voltage
Output Signal When Squelched
Power-Supply Rejection Ratio
Low-Frequency Cutoff
Output Resistance (single ended)
Power-Supply Current
_______________________________________________________________________________________
peak-to-peak signal applied or measured. PECL output voltages are absolute (single-ended) voltages measured at a single
output.
data rate.
deviation from ideal time crossings, measured at the zero-level crossings of the differential output per ANSI X3.230,
Annex A.
quency bandwidth at 75% of the maximum data rate). For Fibre Channel and Gigabit Ethernet applications, the peak-to-
peak random jitter is 14.1-times the RMS random jitter.
20log (V
PARAMETER
LOS-DEASSERT
/ V
LOS-ASSERT
(Notes 2, 3)
(Notes 2, 4)
(Note 6)
(Notes 2, 7)
(Notes 7, 8)
R
R
R
R
R
R
IN+ to IN-
LEVEL = open, R
LEVEL = GND, R
I
I
Outputs AC-coupled
f < 2MHz
C
C
Figure 2
LOS
LOS
TH
TH
TH
TH
TH
TH
AZ
AZ
CC
= 2.5kΩ
= 2.5kΩ
= 7kΩ
= 7kΩ
= 20kΩ
= 20kΩ
= open
= 0.1µF
= -30µA
= +1.2mA
= +3.0V to +5.5V, T
).
LOAD
LOAD
CONDITIONS
= 50Ω
= 75Ω
A
= -40°C to +85°C. Typical values are at V
1100
2.20
18.0
MIN
550
2.2
9.9
2.4
10
97
85
0
1270
TYP
41.5
100
100
230
100
2.5
4.4
4.8
8.5
11
16
27
67
80
20
20
50
CC
8
1
2
2
= +3.3V, T
0.450
MAX
1200
1200
1800
13.6
43.0
155
111
400
103
115
25
76
A
= +25°C,
UNITS
µV
ps
Gbps
ps
MHz
kHz
mA
mV
mV
mV
mV
mV
mV
mV
mV
mV
dB
µA
dB
ps
µs
RMS
RMS
V
V
p-p

Related parts for MAX3768CUB-T