1812J1000682MCTE03 Syfer, 1812J1000682MCTE03 Datasheet - Page 15

no-image

1812J1000682MCTE03

Manufacturer Part Number
1812J1000682MCTE03
Description
EMI Filters 1812 .0068uF 100V C0G 20% X2Y Filter
Manufacturer
Syfer
Datasheet

Specifications of 1812J1000682MCTE03

Product Category
EMI Filters
Rohs
yes
28
Description
A range of miniature dc and ac feedthrough capacitors
rated at 10A. Capacitance values from 1.3nF to 1.5μF. Rated
voltages from 30Vdc to 600Vdc and 250Vac. RoHS compliant.
Case style
Ratings and characteristics
Product range
2
Mechanical details
600Vdc are dual rated at 250Vac. Order as a 600Vdc part.
Rated Current, I
Insulation Resistance
dc Resistance
Operating Temperature Range
1
For temperature θ, I
Mounting hardware
Terminals & Case
Weight
Maximum
torque:
Case
style
SLQ
Current derating between 50ºC and 85ºC
SLU
EMI Power Filters - 10A - SLQ & SLU Range
&
Capacitance
Ø9 (0.35)
max.
(±20%)
Value
100nF
200nF
300nF
600nF
900nF
Resin
fill
1.3nF
3.3nF
4.7nF
1.5µF
- Dimensions - mm (inches)
SLQ
R
M2
terminals
SLU
θ
= I
Voltage
- Thread ¼” x 28 UNF - 2A
8 A/F fixing nut and crinkle washer
Nickel plated brass
5g
Terminals - 0.2Nm (1.77lbf in)
(use 2 spanners)
Mounting thread - 1Nm (8.85lbf in)
R
Rated
2
2
2
Vdc
400
250
160
100
600
600
600
63
30
- Thread M6x 75 - 6g
18 (0.708)
38 (1.5) max.
max.
¼” x 28 UNF - 2A
mounting thread
Voltage
2250
2250
2250
Test
1
>100MΩ
<2mΩ
-55ºC to +85ºC
Vdc
800
500
320
200
126
60
10A @ 50ºC
13 (0.5)
max.
250V 50Hz
Leakage
M2 solder tag
each end
Current
(mA) @
Max.
0.12
0.31
0.45
-
-
-
-
-
-
(0.2)
5.7
kHz
10
3
5
8
-
-
-
-
-
-
kHz
30
10
13
17
-
-
-
1
3
5
100
kHz
27
10
14
20
23
-
-
-
5
EMI Power filters introduction
Insertion Loss
Notes: 1) Please refer to page 34 for ordering information and
EMI Power filters are designed for applications
where currents up to several hundred amps are
required.
Utilising plastic film technology the range includes
high ac and dc working voltage options along
with parts designed and tested to meet the
rigorous demands of EN132400/EN60950 safety
specifications.
Typical applications include: IT servers, telecoms
base stations, MRI room equipment, power
supplies, radar and military vehicles. Filters
designed and tested to meet EN132400/EN60950
class Y2 and Y4 requirements are intended for use
on mains supply systems or lower voltage lines
where safety is important.
Typical Insertion Loss
C
300
kHz
14
20
24
30
33
37
-
-
-
mounting details.
2) This range available as multiway assemblies for cost and
space saving. Please refer to page 35.
in 50 Ω system
-100
MHz
-20
-40
-60
-80
24
30
34
40
43
47
1
-
-
-
0
100k
MHz
10
14
17
44
50
50
50
51
55
7
100nF
600nF
1.5µF
1M
MHz
30
16
24
27
(dB)
-
-
-
-
-
-
Frequency (Hz)
100
MHz
26
34
37
70
74
74
80
83
87
10M
MHz
300
36
44
47
-
-
-
-
-
-
100M
GHz
46
54
57
84
90
90
90
90
90
1
1.3nF
4.7nF
Configuration
Circuit
1G
C
Description
A range of miniature dc feedthrough capacitors rated at 20A.
Capacitance values from 5nF to 12μF. Rated voltages from
30Vdc to 600Vdc and 250Vac. RoHS compliant.
Product range
2
Case style SLE
Mechanical details
600Vdc are dual rated at 250Vac. Order as a 600Vdc part.
Mounting hardware
Terminals & Case
Weight
Maximum
torque:
Case
style
SLE
Capacitance
(±20%)
Value
100nF
200nF
300nF
800nF
10nF
20nF
50nF
80nF
12µF
5nF
1µF
2µF
4µF
5µF
7µF
M3 terminals
22 (0.867)
- Dimensions - mm (inches)
50 (1.969) max.
36 (1.417) max.
19 A/F fixing nut and crinkle washer
Nickel plated brass
25g
Terminals - 0.5Nm (4.42lbf in)
(use 2 spanners)
Mounting thread - 7Nm (61.96lbf in)
Voltage
Rated
2
2
2
2
2
2
2
2
Vdc
400
250
160
100
600
600
600
600
600
600
600
600
80
63
30
(0.315)
M16 x 1
mounting thread
8
Voltage
Test
2250
2250
2250
2250
2250
1250
1250
1250
Vdc
800
500
320
200
160
126
60
250V 50Hz
Leakage
Current
(mA) @
Max.
0.5
1.9
4.7
7.5
9.4
19
28
1
-
-
-
-
-
-
-
Ø20 (0.787)
Resin fill
both ends
max.
kHz
10
10
16
18
21
26
4
5
-
-
-
-
-
-
-
-
kHz
30
12
14
20
26
28
31
36
-
-
-
-
-
-
-
-
EMI Power Filters - 20A - SLE Range
Insertion Loss
Notes: 1) Please refer to page 34 for ordering information and
Ratings and characteristics
100
kHz
22
24
30
36
38
41
46
Rated Current, I
Insulation Resistance
dc Resistance
Temperature Range
1
For temperature θ, I
-
-
-
-
-
-
-
-
Current derating between 50ºC and 85ºC
C
Typical Insertion Loss
-100
-20
-40
-60
-80
mounting details.
2) This range available as multiway assemblies for cost and
space saving. Please refer to page 35.
300
kHz
12
14
20
24
32
34
40
46
48
51
56
0
1
3
8
-
10k
in 50 Ω system
800nF
MHz
12µF
10
18
22
24
30
34
42
44
50
56
58
60
62
4µF
1
2
6
R
100k
θ
= I
MHz
58
70
74
79
86
10
17
24
30
38
42
44
50
50
51
52
R
(dB)
MHz
Frequency (Hz)
100
1M
37
44
46
58
62
70
74
74
82
84
90
90
90
90
90
1
>100MΩ
<1mΩ
-55ºC to +85ºC
20A @ 50ºC
MHz
300
47
54
60
68
72
74
80
84
90
90
90
90
90
-
-
10M
GHz
57
64
70
78
82
84
90
90
90
90
90
90
90
90
90
1
100M
Configuration
300nF
50nF
5nF
Circuit
C
1G
29

Related parts for 1812J1000682MCTE03