MAX1273CUA+T

Manufacturer Part Number
MAX1273CUA+T
Description
Analog to Digital Converters - ADC FAULT-PROTECTED 12-BIT ADC
Manufacturer
Maxim Integrated
Datasheet

Specifications of MAX1273CUA+T

Rohs
yes
Number Of Channels
1
Architecture
SAR
Conversion Rate
87 KSPs
Resolution
12 bit
Input Type
Single-Ended
Interface Type
QSPI, Serial (SPI, Microwire)
Operating Supply Voltage
4.75 V to 5.25 V
Maximum Power Dissipation
727 mW
Number Of Converters
1
To use an external reference, disable the internal buffer
by setting the REF bit in the 8-bit control word to zero
(see Table 1), and apply a reference voltage to REF. Use
an external reference voltage ranging from 2.40V to
4.18V. External reference voltages less than 4.096V
increase the ratio of RMS noise to the LSB value (full
scale / 4096) resulting in performance degradation (loss
of effective bits—ENOB).
The REF input impedance is a minimum of 4.8kΩ for
DC currents; therefore, the external reference must be
able to source 850μA during conversions and have an
output impedance of less than 10Ω. Bypass REF with a
1μF capacitor to GND as close to REF as possible
(Figure 7b).
To save power, configure the ADC for a low-current
shutdown mode by setting the PD bit in the control
byte. The MAX1272/MAX1273 features four program-
mable power-down modes: delayed standby power-
down, immediate standby power-down, delayed full
power-down, and immediate full power-down. Select
standby or full power-down by programming MODE1 in
the input control byte (Table 4). Select delayed or
immediate power-down by programming MODE0 in the
input control byte. Use the MODE0 bit to choose when
the part enters the power-down state. For example,
when MODE0 of the control byte is 0, the device
remains powered up until after the current conversion
ends (Figure 8). On the other hand, if MODE0 = 1, the
device powers down on the falling edge of the eighth
Figure 7a. Internal Reference Configuration
AutoShutdown is a trademark of Maxim Integrated Products, Inc.
MAX1272
MAX1273
______________________________________________________________________________________
with Software-Selectable Input Range
REF
Power-Down Modes
External Reference
C
REF
1.0μF
Fault-Protected, 12-Bit ADCs
serial clock cycle and no conversion takes place
(Figure 9). In all power-down modes, the interface
remains active with the conversion results available at
DOUT. Additionally, the input overvoltage protection
remains active in all power-down modes (MAX1272).
The first high bit on DIN after CS falls (start condition)
powers up the MAX1272/MAX1273 from any software-
selected power-down condition. With external refer-
ence mode, device power-up time from full power-
down is typically 10μs. Send a control byte and allow
10μs for the device to wake up from full power-down.
The next received control byte initiates a conversion.
When in internal reference mode, full power-down
mode disables the internal reference and reference
buffer. Only the interface circuitry remains active for
reading conversion results. Send a control byte and
allow 2ms (C
tle and the MAX1272/MAX1273 to wake up from full
power-down mode. The next received control byte initi-
ates a conversion.
The MAX1272/MAX1273 automatically enter standby
power-down mode after each conversion without requir-
ing any startup time on the next conversion.
The MAX1272/MAX1273 feature a fully compatible
SPI/QSPI and MICROWIRE serial interface. For SPI and
QSPI, clear CPOL and CPHA in the microcontroller’s
SPI control registers.
Figure 7b. External Reference Configuration
MAX1272
MAX1273
REF
= 1μF) for the internal reference to set-
REF
C
REF
1.0μF
OUT
AutoShutdown™
Digital Interface
MAX6064
GND
5V
IN
13

Related parts for MAX1273CUA+T