TLP150-M EMERSON-NETWORKPOWER [Emerson Network Power], TLP150-M Datasheet - Page 3

no-image

TLP150-M

Manufacturer Part Number
TLP150-M
Description
150 W on main channel with only 200 LFM
Manufacturer
EMERSON-NETWORKPOWER [Emerson Network Power]
Datasheet
Notes
1 Free air convection. Maximum continuous output power not to exceed 100 W. Refer to
2 200 LFM forced air cooling from the ac input side. Maximum continuous output power not
3 Figure is peak-to-peak for room temperature rating. Output noise measurements are made
4 CAUTION: Allow a minimum of 1 second after disconnecting line power when making
5 No external filtering required during conducted emissions testing but some applications
6 This product is only for inclusion by professional installers within other equipment and
7 Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G.
8 Replace the ‘J’ at the end of the model number with ‘FJ’ when the optional standby output
9 12 V (fan) present when main output is present. An optional 5 Vsb (standby) output is
10 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant. TSE RoHS 5/6
11 NOTICE: Some models do not support all options. Please contact your local Emerson
Ordering Information
Output Voltage
Figure 1 for the derating curve.
to exceed 150 W.
across a 20 MHz bandwidth using a 6 inch twisted pair, terminated with a 10 µF tantalum
capacitor and a 0.1 µF ceramic capacitor.
thermal measurements. For optimum reliability no part of the heatsink should exceed 115
°C and no semi-conductor case temperature should exceed 120 °C.
may require additional filtering to achieve system compliance. Compliance with radiated
EMI specifications may require mounting in a suitable enclosure.
must not be operated as a stand alone product.
and/or remote ON/OFF control is required
e.g. TLP150N-99S12FJ.
available whenever ac input is present, regardless of remote ON/OFF signal status.
(non Pb-free) compliant versions may be available on special request, please contact your
local sales representative for details.
representative or use the on-line model number search tool at
http://www.powerconversion.com to find a suitable alternative..
12 V
24 V
Dimensions in Inches (mm)
Min
0 A
0 A
J1
ø0.156 (4 Places)
1
Max (free air)
Neutral
Live
J2
8.4 A
4.2A
Output Current
Ground/Earth
(1,4)
Outline Dimensions
5.000 (127.00)
4.550 (115.57)
Max (forced air)
12.5A
6.3 A
Figure 2: Mechanical Drawing
(2,4)
0.225 (5.72)
120 mV
240 mV
Ripple
150 W
100 W
FAN
0 W
R88
J3
0 C
1
DERATING CURVE Output Power (Watts)
J4
1
1
Total Regulation
NATURAL CONVECTION COOLING
10 C
FORCED AIR COOLING
Figure 1: Derating Curve
±3.0%
±3.0%
200 LFM (1.0 m/s)
20 C
Trimmer Adjust
Output Voltage
30 C
TLP150N-99S12J
TLP150N-99S24J
Model Numbers
40 C
Embedded Power for
Business-Critical Continuity
50 C
60 C
Total Height
1.250 (31.75)
1
J301
70 C
75 W
50
W
Rev.12.23.08_140
TLP150-M Series
3 of 4