BXA30-48S12J EMERSON-NETWORKPOWER [Emerson Network Power], BXA30-48S12J Datasheet - Page 3

no-image

BXA30-48S12J

Manufacturer Part Number
BXA30-48S12J
Description
Designed to meet telecom power supply interface standard ETS300-132-2
Manufacturer
EMERSON-NETWORKPOWER [Emerson Network Power]
Datasheet
Ordering Information
Notes
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Nominal, at no load.
Low line to high line.
Full load to no-load. For duals, the value stated is for balanced loads.
An optional internal filter is available, which will meet VDE0871 level A,
VDE0878 level A and EN55022 level A. Add the suffix ‘-F’ to the model number,
e.g. BXA30-48S12-FJ. See BXA15 and BXA30 Design Note 100.
For conducted noise operation of the BXA30 to VDE0871, VDE0878 and
EN55022 level B, see BXA15 and BXA30 Design Note 100.
For extended operating temperature, include the heatsink option, ‘-1’ in the
model number. Max. heatsink height is 12.5 mm, e.g. BXA30-48S15-1J
Reverse voltage protection can be implemented by putting a slow blow fuse on
the negative input rail. Rate the fuse for 48 Vdc at 1.5 A and 12 Vdc at 6 A.
The maximum operating ambient temperature, without derating depends on
internal power dissipation and hence efficiency and cooling method. BXA15
and BXA30 Design Note 100 provides detailed thermal calculations and design-
in details.
Test results to-date are 1,590,000 hours @ 46 ˚C. The MTBF figure shown
includes a calculated acceleration factor of 4.1 based on an activation energy of
-0.55 eV.
Visit the Artesyn website to download a copy of Design Note 100.
This model has the same electrical pin-out and pin pitch spacings as the
drawing on the following page. Dimensions are 76.2 x 76.2 x 14.2 mm,
mm.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
If remote sense is not used, connect +sense to +vout and -sense to -vout.
The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special
request, please contact your local sales representative for details.
NOTICE: Some models do not support all options. Please contact your local
Artesyn representative or go to www.powerconversion.com to find a suitable
alternative
36-75 Vdc
36-75 Vdc
36-75 Vdc
36-75 Vdc
36-75 Vdc
36-75 Vdc
36-75 Vdc
36-75 Vdc
VOLTAGE
9-18 Vdc
INPUT
VOLTAGE
OUTPUT
±12.0 V
±15.0 V
12.0 V
15.0 V
±5.0 V
5.0 V
3.3 V
3.3 V
5.0 V
CURRENT (MAX.)
OUTPUT
±1.25 A
±2.5 A
±1.0 A
5.0 A
6.0 A
8.0 A
5.0 A
2.5 A
2.0 A
CURRENT
100 mA
INPUT
30 mA
30 mA
30 mA
30 mA
30 mA
30 mA
30 mA
30 mA
±
0.3
(1)
EFFICIENCY
TYPICAL
80%
75%
81%
80%
85%
87%
80%
84%
86%
LINE
±0.2%
±0.2%
±0.2%
±0.4%
±0.2%
±0.2%
±0.4%
±0.4%
±0.4%
REGULATION
(2)
LOAD
±0.2%
±0.2%
±0.2%
±1.0%
±0.2%
±0.2%
±0.4%
±0.4%
±0.4%
Embedded Power for
Business-Critical Continuity
(3)
BXA30-48S3V3/8J
BXA30-48S3V3J
NUMBER
BXA30-48D05J
BXA30-48D12J
BXA30-48D15J
BXA30-12S05J
BXA30-48S05J
BXA30-48S12J
BXA30-48S15J
MODEL
(4,6,14,15)
(11)
Rev.12.17.07
bxa30
3 of 5