TP82510 InnovASIC Inc, TP82510 Datasheet - Page 11

no-image

TP82510

Manufacturer Part Number
TP82510
Description
ASYNCHRONOUS SERIAL CONTROLLER
Manufacturer
InnovASIC Inc
Datasheet
IA82510
ASYNCHRONOUS SERIAL CONTROLLER
ERRATA
PLEASE NOTE:
Production Version -01, Errata
The following errata are known problems with the -01 version of the IA82510. This is inclusive of
all package types and environment grades. A workaround to the identified problem has been
provided where possible. ALL ERRATA LISTED IN PRODUCTION VERION -00 HAVE
BEEN FIXED IN THIS VERSION OF THE DEVICE UNLESS OTHERWISE NOTED.
-00 Errata not fixed in this Production Version:
1. Problem: Device does not operate at 8 MHz in divide-by-one mode
New Errata for Production Version -01:
2. Problem: RX FIFO locks up unexpectedly just after configuration and before starting
3. Problem: Unreliable transmits in AUTO TX mode.
Copyright
innovASIC
Analysis: System testing revealed this operational deficiency.
Workaround: Switch to divide-by-two mode using 2X clock input
reception.
Analysis: An RCM command is executed with data of xB8. This is an “enable RX”, “flush RX
machine”, “flush RX FIFO”, and “lock RX FIFO” command done in a single instruction. The
“flush RX machine” should unlock the RX FIFO, creating a conflict with the simultaneous
“lock RX FIFO” command. The original Intel device apparently ignores or gives the “lock RX
FIFO” command lower priority in this case. The IA82510 has this priority reversed.
Apparently, the application software in this case expected the “lock RX FIFO” command to
fail.
Workaround: Do not execute a “flush RX FIFO” and “lock RX FIFO” command
simultaneously. Break up into separate RCM commands.
Analysis: Many systems use the RTS output to activate the line transceiver. When the
Transmit Mode field in the TMD register is set to semi-auto or automatic mode, RTS is
controlled by the TX state machine. On the first character, RTS asserts at the same time as
the start bit on the TXD output, whereas the original Intel device asserts RTS a full bit time
before assertion of the start bit on TXD. At full temperature range, the width of the start bit
When using the -01 version of the IA82510, please refer to the errata section,
"Production Version -01, Errata".
When using the -00 version of the IA82510, please refer to the errata section,
"Production Version -00, Errata".
2001
The End of Obsolescence
ENG211001219-01
Page 11 of 14
As of Production Ver. 01
Data Sheet
www.innovasic.com
Customer Support:
1-888-824-4184