Preliminary Technical Data
FEATURES
High accuracy supports 50 Hz/60 Hz IEC62053-21
Less than 0.1% error over a dynamic range of 500 to 1
Compatible with 3-phase 3-wire delta and 3-phase 4-wire Wye
Supplies average active power on the frequency outputs F1 and F2
High frequency output (CF) is intended for calibration and
Logic output REVP indicates a potential miswiring or negative
Direct drive for electromechanical counters and 2-phase stepper
Proprietary ADCs and DSP provide high accuracy over large
On-chip power supply monitoring
On-chip creep protection (no load threshold) based on the sum
On-chip reference 2.4 V ± 8% (25 ppm/°C typical) with external
Single 5 V supply, low power (TBD mW typical)
Low cost CMOS process
GENERAL DESCRIPTION
The ADE7752B
intended for use in any 3-phase distribution system and has
enhanced features that make it better suited for 3-phase 3-wire
applications compared to the ADE7752/52A.
Rev. PrA
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice. No
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registered trademarks are the property of their respective owners.
configurations
supplies instantaneous active power
power on the sum of all phases
motors (F1 and F2)
variations in environmental conditions and time
of the three phases
overdrive capability
1
is an accurate active energy measurement IC
VBP
VCP
VAP
IBP
IBN
ICP
ICN
IAP
IAN
VN
16
15
10
14
13
5
6
7
8
9
2.4V REF
AGND
11
4kΩ
REF
ADC
ADC
ADC
ADC
ADC
ADC
12
IN/OUT
Polyphase Energy Metering IC with Pulsed
FUNCTIONAL BLOCK DIAGRAM
CORRECTION
CORRECTION
CORRECTION
PHASE
PHASE
PHASE
HPF
HPF
HPF
Φ
Φ
Φ
Figure 1.
REVP
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
Fax: 781.461.3113
The no-load threshold and reverse polarity indication are based
on the sum of the three phase energies in the ADE7752B. The
ADE7752B specifications surpass the accuracy requirements as
quoted in the IEC62053-21 standard.
The only analog circuitry used in the ADE7752B is in the
analog-to-digital converters (ADCs) and reference circuit. All
other signal processing (for example, multiplication, filtering,
and summation) is carried out in the digital domain. This
approach provides superior stability and accuracy over
extremes in environmental conditions and over time.
The ADE7752B supplies average active power information on
the low frequency outputs, F1 and F2. These logic outputs can
be used to directly drive an electromechanical counter or to
interface with an MCU. The CF logic output gives
instantaneous active power information. This output is
intended to be used for calibration purposes.
The ADE7752B includes a power supply monitoring circuit on
the V
voltage on V
ADE7752B also resets and no pulses are issued on F1, F2, and CF.
Internal phase matching circuitry ensures that the voltage and
current channels are phase matched. An internal no load
threshold ensures the ADE7752B does not exhibit any creep
when there is no load.
The ADE7752B is available in a 24-lead SOIC package.
1
Patent pending.
4
LPF
LPF
LPF
DD
SCF
DIGITAL-TO-FREQUENCY CONVERTER
18
pin. The ADE7752B remains inactive until the supply
DD
S0
21
X
X
X
ABS
17
reaches 4 V. If the supply falls below 4 V, the
S1
22
Σ
F2
23
© 2006 Analog Devices, Inc. All rights reserved.
ADE7752B
MONITOR
SUPPLY
POWER
V
F1
24
DD
3
CF
1
19
20
2
DGND
CLKIN
CLKOUT
ADE7752B
www.analog.com
Output

Related parts for ADE7752BARW

ADE7752BARW Summary of contents

Page 1

Preliminary Technical Data FEATURES High accuracy supports 50 Hz/60 Hz IEC62053-21 Less than 0.1% error over a dynamic range of 500 to 1 Compatible with 3-phase 3-wire delta and 3-phase 4-wire Wye configurations Supplies average active power on the frequency ...

Page 2

ADE7752B TABLE OF CONTENTS Features .............................................................................................. 1 General Description ......................................................................... 1 Table of Contents .............................................................................. 2 Specifications..................................................................................... 3 Timing Characteristics ................................................................ 5 Absolute Maximum Ratings............................................................ 6 ESD Caution.................................................................................. 6 Pin Configuration and Function Descriptions............................. 7 Typical Performance Characteristics ............................................. 9 ...

Page 3

Preliminary Technical Data SPECIFICATIONS ± 5%, AGND = DGND = 0 V, on-chip reference, CLKIN = 10 MHz Table 1. Parameter Conditions 1, 2 ACCURACY Measurement Error on Voltage channel with full-scale signal (±500 ...

Page 4

ADE7752B Parameter Conditions LED_A, LED_B, LED_C Output Low 4.75 V SINK DD Output High Source POWER SUPPLY For specified performance ± See the Terminology ...

Page 5

Preliminary Technical Data TIMING CHARACTERISTICS ± 5%, AGND = DGND = 0 V, on-chip reference, CLKIN = 10 MHz Table 2. 1,2 Parameter Conditions and F2 pulse width (logic high) 1 ...

Page 6

ADE7752B ABSOLUTE MAXIMUM RATINGS T = 25°C, unless otherwise noted. A Table 3. Parameter V to AGND DGND DD Analog Input Voltage to AGND VAP, VBP, VCP, VN, IAP, IAN, IBP, IBN, ICP, and ICN Reference Input ...

Page 7

Preliminary Technical Data PIN CONFIGURATION AND FUNCTION DESCRIPTIONS Table 4. Pin Function Descriptions Pin No. Mnemonic Description 1 CF Calibration Frequency Logic Output. The CF logic output gives instantaneous active power information. This output is intended to be used for ...

Page 8

ADE7752B Pin No. Mnemonic Description 20 CLKOUT A crystal can be connected across this pin and CLKIN as described previously to provide a clock source for the ADE7752B. The CLKOUT pin can drive one CMOS load when an external clock ...

Page 9

Preliminary Technical Data TYPICAL PERFORMANCE CHARACTERISTICS Figure 4. Error as a Percent of Reading with Internal Reference (Wye Connection) Figure 5. Error as a Percent of Reading over Power Factor with Internal Reference (Wye Connection) Figure 6. Error as a ...

Page 10

ADE7752B Figure 10. Error as a Percent of Reading over Frequency with an Internal Reference (Wye Connection) Figure 11. Error as a Percent of Reading over Power Supply with External Reference (Wye Connection) Preliminary Technical Data Figure 12. Channel 1 ...

Page 11

Preliminary Technical Data TERMINOLOGY Measurement Error The error associated with the energy measurement made by the ADE7752B is defined by the following formula: ⎧ Energy Registered by ADE = Percentage Error ⎨ True Energy ⎩ Error between Channels The high-pass ...

Page 12

ADE7752B TEST CIRCUIT 1MΩ 220V 1kΩ 100nF 10μ LOAD ABS DD 1kΩ IAP 33nF ADE7752B RB 1kΩ IAN 33nF CLKOUT 20 IBP 7 SAME AS IAP, ...

Page 13

Preliminary Technical Data THEORY OF OPERATION The six signals from the current and voltage transducers are digitized with ADCs. These ADCs are 16-bit second-order ∑-Δ with an oversampling rate of 833 kHz. This analog input structure greatly simplifies transducer interface ...

Page 14

ADE7752B This is the correct active power calculation. INSTANTANEOUS POWER SIGNAL V × CURRENT VOLTAGE INSTANTANEOUS POWER SIGNAL V × I × cos(60° VOLTAGE 60° Figure 16. DC Component of Instantaneous Power Signal NONSINUSOIDAL VOLTAGE ...

Page 15

Preliminary Technical Data ANALOG INPUTS CURRENT CHANNELS The voltage outputs from the current transducers are connected to the ADE7752B current channels, which are fully differential voltage inputs. IAP, IBP, and ICP are the positive inputs for IAN, IBN, and ICN, ...

Page 16

ADE7752B TYPICAL CONNECTION DIAGRAMS CURRENT CHANNEL CONNECTION Figure 19 shows a typical connection diagram for the current channel (IA). A current transformer (CT) is the current trans- ducer selected for this example. Notice the common-mode voltage for the current channel ...

Page 17

Preliminary Technical Data Figure 21 shows the connections of the ADE7752B analog inputs with the power lines in a 3-phase 3-wire delta service. Cf Ra* Rb* VR* Rb* ANTIALIASING FILTERS CT PHASE A PHASE C SOURCE Rf CT PHASE B ...

Page 18

ADE7752B POWER SUPPLY MONITOR The ADE7752B contains an on-chip power supply monitor. The power supply ( monitored continuously by the ADE7752B power up, when the supply is less than 4V ±2% and V than 1.9 V ...

Page 19

ADE7752B HPF AND OFFSET EFFECTS Figure 24 shows the effect of offsets on the active power calculation. An offset on the current channel and voltage channel contributes a dc component after multiplication as shown in Figure 24. Since this dc ...

Page 20

ADE7752B DIGITAL-TO-FREQUENCY CONVERSION After multiplication, the digital output of the low-pass filter contains the active power information of each phase. However, since this LPF is not an ideal brick wall filter implementation, the output signal also contains attenuated components at ...

Page 21

Preliminary Technical Data POWER MEASUREMENT CONSIDERATIONS Calculating and displaying power information always have some associated ripple that depends on the integration period used in the MCU to determine average power as well as the load. For example, at light loads, ...

Page 22

ADE7752B TRANSFER FUNCTION FREQUENCY OUTPUTS F1 AND F2 The ADE7752B calculates the product of six voltage signals (on current channel and voltage channel) and then low-pass filters this product to extract active power information. This active power information is then ...

Page 23

Preliminary Technical Data Example 3 In this example, the ADE7752B is connected to a 3-phase 3- wire delta service as shown in Figure 21. The total active energy calculation processed in the ADE7752B can be expressed as Total Active Power ...

Page 24

Preliminary Technical Data SELECTING A FREQUENCY FOR AN ENERGY METER APPLICATION As shown in Table 5, the user can select one of seven frequencies. This frequency selection determines the maximum frequency on F1 and F2. These outputs are intended to ...

Page 25

Preliminary Technical Data Table 10. CF, F1, and F2 Minimum Frequency at No Load Threshold SCF S1 S0 F1, F2 Minimum (Hz 6.94E − 1.39E − 3.47E − 05 ...

Page 26

... ADE7752B OUTLINE DIMENSIONS 0.30 (0.0118) 0.10 (0.0039) COPLANARITY 0.10 ORDERING GUIDE Model 1 ADE7752BARWZ 1 ADE7752BARWZ-RL ADE7752BARW ADE7752BARW-RL EVAL-ADE7752BEB Pb-free part small outline wide body package in tubes. 15.60 (0.6142) 15.20 (0.5984 7.60 (0.2992) 7.40 (0.2913 2.65 (0.1043) 2.35 (0.0925) 1.27 (0.0500) 0.51 (0.020) SEATING 0.33 (0.0130) PLANE BSC 0.31 (0.012) 0.20 (0.0079) COMPLIANT TO JEDEC STANDARDS MS-013-AD CONTROLLING DIMENSIONS ARE IN MILLIMETERS ...

Page 27

Preliminary Technical Data NOTES © 2006 Analog Devices, Inc. All rights reserved. Trademarks and registered trademarks are the property of their respective owners. PR05905-0-1/06(PrA) Rev. PrA | Page ADE7752B ...