3RHP CRYDOM [Crydom Inc.,], 3RHP Datasheet

no-image

3RHP

Manufacturer Part Number
3RHP
Description
Hybrid Solid State Contactors
Manufacturer
CRYDOM [Crydom Inc.,]
Datasheet
Part Number Nomenclature
CONTROL SPECIFICATIONS
Control Voltage Suffix
Coil Voltage Range
Min. Turn-On Voltage
Min. Turn-Off Voltage
Coil Power Consumption, Inrush
Coil Power Consumption, Sealed
Coil Terminals
OUTPUT SPECIFICATIONS
Voltage suffix
Operating Voltage (50/60Hz)
Maximum Off-State Leakage Current per channel
Load Current suffix
Maximum Load Current per Phase @ 40°C
Power terminals / wire range
Screw torque requirements
GENERAL SPECIFICATIONS
Input to Output Dielectric Isolation.
Input/Output to Ground Dielectric Isolation.
Contacts (Double Break )
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Max. Turn-On Time
Max. Turn-Off Time
Maximum Number of Operations per Minute
Lifetime @ Rated Load Current, 40°C ambient
temp, 30 operations/min, Rated Vcontrol
Weight (typical)
1
2
3
4
3
Specificationts @ 25°C unless otherwise noted.
See Derating Curves for additional operational conditions.
The RHP includes a Solid-State Relay. Therefore, the output is never completely open.
The RHP includes an overtemperature protection for the Solid-State Module.
Three
Phase
Device
RHP
SERIES
3
12
Operating
Voltage VAC
50/60 Hz
12: 120 V 1-phase
24: 240 V 3-phase
or 1-phase
28: 280 V 3-phase
60: 600 V 3-phase
20 - 26 VAC, 50/60 Hz
1
6.6 VA @ 24 VAC
10 in lb (1.13 Nm)
56 VA @ 24 VAC
1
1
4
40
20 VAC
12 VAC
2
Load Current
40: 40 Amps
50: 50 Amps
E
3
head screws / AWG#14 - AWG#8
3 Phase Contactor
AC Input
40-50 Amp
280/600 VAC
Dual quick connect and Binder
D5
Combined SSR and EMR advantages
Lifetime >2 million operations @ full load
No heat sink required
Input status LED indicator
Wire, lug or quick connect termination
DP contactor footprint
CE compliant & UL/cUL recognized
/Control Voltage
0.05 mA @ 240 VAC
18 in lbs (2.1 Nm)
Nominal Coil
40 A Resistive
24 - 280 VAC
D12: 12 VDC
D24: 24 VDC
100 - 130 VAC, 50/60 Hz
G: 220 VAC
F: 120 VAC
D5: 5 VDC
E: 24 VAC
6.6 VA @ 120 VAC
56 VA @ 120 VAC
10 in lb (1.13 Nm)
28
40
16.6 mS @ 60 Hz / 20 mS @ 50 Hz
32 mS @ 60 Hz / 40 mS @ 50 Hz
100 VAC
24 VAC
F
Three Normally Open
30 operations per min
> 2 Million operations
-40°C to 100°C
540 grs (1.19 lb)
-20°C to 75°C
4000 VAC
2500 VAC
Derating Curves
Dual quick connect and Box
lugs / AWG#14 - AWG#6
208 - 240 VAC, 50/60 Hz
0.06 mA @ 480 VAC
45
40
35
30
25
20
6.6 VA @ 220 VAC
56 VA @ 220 VAC
25 in lbs (2.9 Nm)
10 in lb (1.13 Nm)
50 A Resistive
48 - 600 VAC
25
208 VAC
48 VAC
60
50
G
35
3 Phase RHP - Hybrid Solid State Contactors
Safe Operating Area
Ambient Temperature, °C
3RHPXX
Power lead size
45
AWG # 6
AWG # 8
CONTROL SPECIFICATIONS
Control Voltage Suffix
Control Voltage Range
Max. Reverse Voltage
Min. Turn-On Voltage
Min. Turn-Off Voltage
Input Current
Input Connector
OUTPUT SPECIFICATIONS
Voltage suffix
Operating Voltage (50/60Hz)
Maximum Off-State Leakage Current per channel
Load Current suffix
Maximum Load Current per Phase @ 40°C
Power terminals / wire range
Screw torque requirements
GENERAL SPECIFICATIONS
Input to Output Dielectric Isolation
Input/Output to Ground Dielectric Isolation
Contacts (Double Break)
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Max. Turn-On Time
Max. Turn-Off Time
Maximum Number of Operations per Minute
Lifetime @ Rated Load Current, 40°C ambient
temp, 30 operations/min, Rated Vcontrol
Weight (typical)
1
2
3
4
40
Specificationts @ 25°C unless otherwise noted.
See Derating Curves for additional operational conditions.
The RHP includes a Solid-State Relay. Therefore, the output is never completely open.
The RHP includes an overtemperature protection for the Solid-State Module.
XX
55
65
3
75
1
1
1
4
2
5.31 in lb (0.6 Nm)
55
50
45
40
35
30
25
20
12mA @ 5 VDC
4.5 - 5.5 VDC
head screws / AWG#14 - AWG#8
25
-5.5 VDC
Dual quick connect and Binder
4.5 VDC
3
1 VDC
D5
3 Phase Contactor
DC Input
40-50 Amp
120/240 VAC
0.05 mA @ 120 VAC
18 in lbs (2.1 Nm)
Combined SSR and EMR advantages
Lifetime >2 million operations @ full load
No heat sink required
DC logic compatible input
Input status LED indicator
Wire, lug or quick connect termination
DP contactor footprint
CE compliant & UL/cUL recognized
100 - 120 VAC
40 A Resistive
35
16.6 mS @ 60 Hz / 20 mS @ 50 Hz
32 mS @ 60 Hz / 40 mS @ 50 Hz
12
40
Safe Operating Area
Three Normally Open
30 operations per min
> 2 Million operations
Ambient Temperature, °C
Power lead size
5.31 in lb (0.6 Nm)
540 grs (1.19 lb)
3RHPXX
12mA @ 12 VDC
-40°C to 100°C
-20°C to 75°C
45
10 - 15 VDC
4000 VAC
2500 VAC
-15.5 VDC
AWG # 6
AWG # 8
9.5 VDC
2 VDC
D12
50
55
Dual quick connect and Box
lugs / AWG#14 - AWG#6
XX
0.06 mA @ 240 VAC
25 in lbs (2.9 Nm)
208 - 240 VAC
50 A Resistive
5.31 in lb (0.6 Nm)
12mA @ 24 VDC
65
24
50
22 - 27 VDC
-27.5 VDC
9.5 VDC
2 VDC
D24
75

Related parts for 3RHP

3RHP Summary of contents

Page 1

... VAC 3 Three Normally Open 4 -20°C to 75°C -40°C to 100°C 16 operations per min > 2 Million operations 540 grs (1.19 lb) 50 3RHPXX Power lead size 40 AWG # 6 AWG # Safe Operating Area ...

Page 2

Typical Electrical Connection for 3 Phase Applications (For output voltage options 24, 28, 60) 3 Phase AC AC Input/Control Voltage ~ ~ ~ ( input versions) Operating Voltage 5L3 3L2 VLL 1L1 Input/Control Voltage (D5, ...

Related keywords