Figure 5. PSTN Line Interface.
1. Currently Limiting PSTN Protection Line
2. Over Voltage and Lightning Protection.
Device.
Currently limiting devices are mandatory to meet
UL safety standards. For FCC Part 68 approval,
the current limiting components identified as F1
and F2 in dashed Box #1 must also survive FCC
Part 68 surge testing.
Application Note #126, Supplemental PSTN Line
Protection, for more details. Refer to Application
Note # 130, Summary of Recommend Suppliers,
for a list of suppliers and associated part numbers.
A. A Polyfuse (rated at 0.15 amps) is preferred
B. Resistors (10Ω carbon film or 1/8 watt
C. Although CSA CS-03 Part 1 (Canada) follows
A. The required UL1950 and FCC Part 68 surge
because it resets automatically upon removal
of the current flow.
are also acceptable. Refer to Application Note
#130 for a complete list of recommended
vendors and associated part numbers.
minimum) may be used in Canada, as Canada
has no requirements that PSTN equipment be
operational after a Type B surge test.
the requirements of FCC Part 68 (USA),
Cermetek
(Canada) and/or a certified independent lab to
verify compliance.
10Ω resistors (carbon film or SMD parts 1/8
watt minimum) as described in paragraph B
above.
protection (identified as D1 in dashed Box 2)
must be supplied externally. The purchaser
must include some form of surge protection as
described herein to obtain FCC Part 68
recommends
For Canada, use either
Non-resettable devices
Refer to Cermetek
contacting
DOT
Page 7
3. EMI/RFI Suppression.
B. In most environments, 2 terminal surge
Additional suppression, if required, may be added
as described below in Sections 3A-3B without
adversely affecting FCC Part 68 approval or
UL1950 listing.
A. To provide adequate EMI/RFI suppression,
B. Capacitors C1 and C2 should not exceed
approval and to maintain UL1950 Edition 3
listing.
suppressors are adequate.
environments, use an external 3 terminal
device (as indicated in Figure 5) with an earth
ground.
the capacitor/inductor network contained in
dashed Box #3 should be located as close to
the RJ11 Jack as possible.
network should be provided with an excellent
ground path to the chassis.
0.005µf. They must have a rating of 1.5KV
and typically are 0.001µf ± 20%. Inductors L1
and L2 may be either individual inductors or a
dual inductor. Refer to Application Note #130
for a complete list of recommended vendors
and associated part numbers.
applications, choose capacitors and inductors
that are UL 1950 listed. The actual values of
the components used may vary depending on
the end product design.
CH1837A/7F/8A Data Access Arrangement Module