GS2975A GENNUM [Gennum Corporation], GS2975A Datasheet - Page 6

no-image

GS2975A

Manufacturer Part Number
GS2975A
Description
Manufacturer
GENNUM [Gennum Corporation]
Datasheet
Table 1-1: Pin Descriptions (Continued)
GS2975A HD-LINX® III Multi-Rate SDI Automatic
Reclocker with Dual Differential Outputs
Data Sheet
41487 - 4
Pin Number
24, 25, 26
27
28
29
30
31
33
34
35
April 2009
Name
SS[0:2]
NC
LOCKED
LOS
VCC_DIG
VEE_DIG
SD/HD
KBB
RCO_MUTE
Type
Bi-directional
No Connect
Output
Output
Power
Power
Output
Analog Input
Power
Description
When AUTO/MAN is HIGH, SS[0:2] are outputs, displaying the data rate to
which the PLL has locked.
When AUTO/MAN is LOW, SS[0:2] are inputs, forcing the PLL to lock only to
a selected data rate
.
Not connected internally.
Lock Detect.
This pin is set HIGH by the device when the PLL is locked.
Loss of Signal.
Set HIGH when there are no transitions on the active DDI[3:0] input.
Most positive power supply connection for the internal glue logic.
Connect to 3.3V.
Most negative power supply connection for the internal glue logic.
Connect to GND.
This signal will be set LOW by the device when the reclocker has locked to
2.97Gb/s (2.967Gb/s) or 1.485Gb/s (1.4835Gb/s), or when a non-SMPTE
standard is applied (i.e. the device is not locked).
It will be set HIGH when the reclocker has locked to 270Mbps.
Controls the loop bandwidth of the PLL.
Serial clock or secondary data output mute.
Assert LOW for reduced power consumption, see
Characteristics.
When RCO_MUTE = LOW, the RCO/DDO1 output is powered down.
When RCO_MUTE = HIGH, the RCO/DDO1 output is active.
NOTE: This is not a logic input pin.
SS2
0
1
1
SS1
1
0
1
SS0
0
1
0
SELECTED/FORCED (Mb/s)
2.2 DC Electrical
1483.5/1485
DATA RATE
2967/2970
270
6 of 27