S-8233BBFT SII [Seiko Instruments Inc], S-8233BBFT Datasheet - Page 8

no-image

S-8233BBFT

Manufacturer Part Number
S-8233BBFT
Description
BATTERY PROTECTION IC (FOR A 3-SERIAL-CELL PACK)
Manufacturer
SII [Seiko Instruments Inc]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S-8233BBFT-TB
Manufacturer:
FUJITSU
Quantity:
316
Part Number:
S-8233BBFT-TB
Manufacturer:
SEIKO
Quantity:
20 000
8
BATTERY PROTECTION IC FOR 3-SERIAL-CELL PACK
S-8233B Series
Test Circuits
(1) Measurement 1 Measurement circuit 1
(2) Measurement 2 Measurement circuit 1
(3) Measurement 3 Measurement circuit 1
(4) Measurement 4 Measurement circuit 2
(5) Measurement 5 Measurement circuit 3
Caution At the Measurement circuit from (1) to (15).
Set V1, V2, and V3 to 3.5 V under normal condition. Increase V1 from 3.5 V gradually. The V1 voltage
when COP = 'H' is over charge detection voltage 1 (V
COP = 'L' is over charge release voltage 1 (V
is over discharge voltage 1 (V
discharge release voltage 1 (V
Remark: The voltage change rate is 150 V/s or less.
Set V1, V2, and V3 to 3.5 V under normal condition. Increase V2 from 3.5 V gradually. The V2 voltage
when COP = 'H' is over charge detection voltage 2 (V
COP = 'L' is over charge release voltage 2 (V
is over discharge voltage 2 (V
discharge release voltage 2 (V
Remark: The voltage change rate is 150 V/s or less.
Set V1, V2, and V3 to 3.5 V under normal condition. Increase V3 from 3.5 V gradually. The V3 voltage
when COP = 'H' is over charge detection voltage 3 (V
COP = 'L' is over charge release voltage 3 (V
is over discharge voltage 3 (V
discharge release voltage 3 (V
Remark: The voltage change rate is 150 V/s or less.
Set V1, V2, V3 to 3.5 V and V5 to 0 V under normal condition. Increase V5 from 0 V gradually. The V5
voltage when DOP = 'H' and COP = 'H', is over current detection voltage 1 (V
Set V1, V2, and V3 to 3.5 V and V5 to 0 V under normal condition. Fix the COVT terminal at V
increase V5 from 0 V gradually. The V5 voltage when DOP = 'H' and COP = 'H' is over current detection
voltage 2 (V
Set V1, V2, and V3 to 3.5 V and V5 to 0 V under normal condition. Fix the COVT terminal at V
increase V5 gradually from 0 V at 400 μs to 2 ms. The V5 voltage when DOP = 'H' and COP = 'H' is over
current detection voltage 3 (V
Set S1 to ON, V1, V2, and V3 to 3.5 V, and V5 to 0 V under normal condition and measure current
consumption. I1 is the normal condition current consumption (I
(I
Set S1 to ON, V1, V2, and V3 to 1.5 V, and V5 to 4.5 V under over discharge condition. Current
consumption I1 is power-down current consumption (I
CELL2
), and I3, the cell 3 current consumption (I
If the device’s CTL logic is “normal” (S-8233BA, S-8233BC, S-8233BE) then set the CTL
voltage at V
If the device’s CTL logic is “reverse” (S-8233BB, S-8233BD) then set the CTL voltage at V
(V4=V1+V2+V3).
IOV2
).
SS
(V4=0V).
IOV3
DD1
DD2
DD3
DU1
DU2
DU3
). Increase V1 gradually. The V1 voltage when DOP = 'L' is over
). Increase V2 gradually. The V2 voltage when DOP = 'L' is over
). Increase V3 gradually. The V3 voltage when DOP = 'L' is over
).
).
).
).
Seiko Instruments Inc.
CD1
CD2
CD3
CELL3
). Further decrease V1. The V1 voltage when DOP = 'H'
). Further decrease V2. The V2 voltage when DOP = 'H'
). Further decrease V3. The V3 voltage when DOP = 'H'
).
CU1
CU2
CU3
PDN
). Decrease V1 gradually. The V1 voltage when
). Decrease V2 gradually. The V2 voltage when
). Decrease V3 gradually. The V3 voltage when
).
OPE
), I2, the cell 2 current consumption
IOV1
).
Rev.4.2
SS
SS
,
,
_00
CC

Related parts for S-8233BBFT