7.11. Temperature Real Time Status Register  Index 62h (If DEV_BANK_EN is 0)
7.12. Temperature Real Time Status Register  Index 62h (If DEV_BANK_EN is 1)
6-3
7-6
Bit
Bit
1
0
7
2
1
0
5
4
3
2
1
0
T4_EXC _STS
T3_EXC _STS
LOCAL_EXC
DEV_T_EXC
T2_EXC
T1_EXC
T8_EXC
T7_EXC
T6_EXC
T5_EXC
T4_EXC
T3_EXC
Name
Name
-
-
R/W
R/W
R/W Default
R/W Default
R
R
R
R
R
R
R
R
R
R
R
R
0
0
0
0
0
0
0
0
0
0
0
0
0
0
A one indicates TEMP4 temperature sensor has exceeded high limit or
below the “high limit –hysteresis” limit. Write 1 to clear this bit, write 0 will
be ignored.
A one indicates TEMP3 temperature sensor has exceeded high limit or
below the “high limit –hysteresis” limit. Write 1 to clear this bit, write 0 will
be ignored.
Set when one of TEMP3~TEMP8 exceeds the high limit. Clear when the
TEMP3~TEMP8 is below the “high limit –hysteresis” temperature.
Reserved
Set when the TEMP2 exceeds the high limit. Clear when the TEMP2 is
below the “high limit –hysteresis” temperature.
Set when the TEMP1 exceeds the high limit. Clear when the TEMP1 is
below the “high limit –hysteresis” temperature.
Set when the local temperature exceeds the high limit. Clear when the
local temperature is below the “high limit –hysteresis” temperature.
Reserved
Set when the TEMP8 exceeds the high limit. Clear when the TEMP8 is
below the “high limit –hysteresis” temperature.
Set when the TEMP7 exceeds the high limit. Clear when the TEMP7 is
below the “high limit –hysteresis” temperature.
Set when the TEMP6 exceeds the high limit. Clear when the TEMP6 is
below the “high limit –hysteresis” temperature.
Set when the TEMP5 exceeds the high limit. Clear when the TEMP5 is
below the “high limit –hysteresis” temperature.
Set when the TEMP4 exceeds the high limit. Clear when the TEMP4 is
below the “high limit –hysteresis” temperature.
Set when the TEMP3 exceeds the high limit. Clear when the TEMP3 is
below the “high limit –hysteresis” temperature.