pan3401 ETC-unknow, pan3401 Datasheet - Page 10

no-image

pan3401

Manufacturer Part Number
pan3401
Description
Ps/2 Optical Mouse Single Chip
Manufacturer
ETC-unknow
Datasheet
All rights strictly reserved any portion in this paper shall not be reproduced, copied or transformed to any other forms without permission
PixArt Imaging Inc.
E-mail:
PixArt Imaging Inc.
PAN3401
7. Mouse Mode Selection
The Set Sampling Rate command is used to set the device operating modes. Whenever the mouse received
command 'FF', it will reset to standard mode (2D3B) mode. After power-on reset is initiated, the mouse is set to
standard PS/2 mode.
The Device ID is available through the PS/2 Read Device Type (0xF2) command. For a device in standard 2D
mode, the device will report an ID of 0x00. For a device in standard 3D mode, the device will report an ID of
0x03.
● Standard 3D Mouse (3D3B) Command Sequence
After Reset, the device will be in standard 2D mode. By sending the Set Sampling Rate command series as
follows, the device is set to standard 3D mode.
Notice that the Set Sampling Rate commands are valid, and the device report rate will be the value of the last
command; that is, 0x50 after this series of commands.
fae_service@pixart.com.tw
Standard 2D mode (2D3B)
Standard 3D mode (3D3B)
Command
Mode
C8
F3
F3
F3
F2
64
50
Device ID
Response
FA, 03
0x00
0x03
FA
FA
FA
FA
FA
FA
PS/2 Optical Mouse Single Chip
.
V1.3, Mar. 2008
10