rx2m-458-5tx2i-458-5 Radiometrix Ltd, rx2m-458-5tx2i-458-5 Datasheet - Page 5

no-image

rx2m-458-5tx2i-458-5

Manufacturer Part Number
rx2m-458-5tx2i-458-5
Description
Uhf Narrow Band Fm Multi Channel Radio Modules
Manufacturer
Radiometrix Ltd
Datasheet
Command
Format
SINGLE nnnnn
GOCHAN xx
LOADMX xx
LOADaa nnnnn
LOADTB nnnnn
RVALUE rrrr
SETPAR
SETSER
SETMOD
GOTEST
<CR>
/
xx = channel number from 00 to 127
aa = two digit channel number from 00 to 15
nnnnn = synthesizer N register value, (up to 65535)
rrrr = synthesizer R register value, (up to 16383)
2400 baud at RS232 level. 8 bit data, no parity, 1 start bit, 1 or 2 stop bits, No flow control.
Transmit (pin 3 on DB9) and Signal Ground (pin 5 on DB9) should be connected to PGM and 0V pin.
Channel
Number
Please observe the following ERC/REC 70-03 (April 2004) Annex 1 recommendation when using the
Non-specific Short Range Device (SRD) band for Telemetry, Telecommand, Alarms, Data in general and
other similar applications.
Frequency Band
E (433.050 - 434.790MHz)
E1 (433.050 - 434.790MHz)
E2 (434.040 - 434.790MHz)
Radiometrix Ltd
N
N
F max
TX
RX
10
11
12
13
14
15
16
0
1
2
3
4
5
6
7
8
9
f
f
RF
Channelspa
f
433MHz
band
433.050
433.075
433.100
433.125
433.150
433.175
433.200
433.225
433.250
433.275
433.300
433.325
433.350
433.375
433.400
433.425
433.450
434.775
Channelspa
f
RF
21
4 .
cing
MHz
cing
N value for TX
/LOAD00 17322
/LOAD01 17323
/LOAD02 17324
/LOAD03 17325
/LOAD04 17326
/LOAD05 17327
/LOAD06 17328
/LOAD07 17329
/LOAD08 17330
/LOAD09 17331
/LOAD10 17332
/LOAD11 17333
/LOAD12 17334
/LOAD13 17335
/LOAD14 17336
/LOAD15 17337
/LOADTB 17338
/LOADMX 69
Description
Set value of N for single channel operation
Serial select of channel xx (0 to 127)
Set highest permitted (serial selected) channel xx (others default to ch0)
Set value of N for channel aa (channels 0 to 15)
Set value of N for channel 16 (channels 17 to 127 then in sequence)
Enter value for R register
Channel selected by 3 bit parallel input (0 to 7). Disable modem
Channel selected by most recent GOCHAN operation
Enable internal modem. Frequency selected by most recent GOCHAN or SINGLE
250Hz test tone modulated transmission
Process entry (Carriage Return = 0D hex )
Clear all buffers
433
25
433
.
TX2M and RX2M serial interface commands
050
kHz
.
050
MHz
25
MHz
10mW
10mW
kHz
1mW
ERP
17322
N value for RX
/LOAD00 16466
/LOAD01 16467
/LOAD02 16468
/LOAD03 16469
/LOAD04 16470
/LOAD05 16471
/LOAD06 16472
/LOAD07 16473
/LOAD08 16474
/LOAD09 16475
/LOAD10 16476
/LOAD11 16477
/LOAD12 16478
/LOAD13 16479
/LOAD14 16480
/LOAD15 16481
/LOADTB 16482
/LOADMX 69
21
<100%
<100%
4 .
Cycle
Duty
<10%
TX2M/RX2M Data Sheet
16466
No spacing
No spacing
Channel
spacing
R
<25kHz
458MHz
band
458.525
458.550
458.575
458.600
458.625
458.650
458.675
458.700
458.725
458.750
458.775
458.800
458.825
458.850
458.875
458.900
458.925
459.100
f
channelspa
f
TCXO
Notes
Audio and voice signals should be
avoided in the band 433.050MHz -
434.790MHz
Power density limited to -13dBm/10
kHz for wideband channels with a
bandwidth greater than 250 kHz
cing
N value for TX
/LOAD00 18341
/LOAD01 18342
/LOAD02 18343
/LOAD03 18344
/LOAD04 18345
/LOAD05 18346
/LOAD06 18347
/LOAD07 18348
/LOAD08 18349
/LOAD09 18350
/LOAD10 18351
/LOAD11 18352
/LOAD12 18353
/LOAD13 18354
/LOAD14 18355
/LOAD15 18356
/LOADTB 18357
/LOADMX 23
13
25
MHz
kHz
, So R=520
N value for RX
/LOAD00 17485
/LOAD01 17486
/LOAD02 17487
/LOAD03 17488
/LOAD04 17489
/LOAD05 17490
/LOAD06 17491
/LOAD07 17492
/LOAD08 17493
/LOAD09 17494
/LOAD10 17495
/LOAD11 17496
/LOAD12 17497
/LOAD13 17498
/LOAD14 17499
/LOAD15 17500
/LOADTB 17501
/LOADMX 23
page 5