bxb50s Astec Powe, bxb50s Datasheet

no-image

bxb50s

Manufacturer Part Number
bxb50s
Description
Bxb50 Series Single Output
Manufacturer
Astec Powe
Datasheet
BXB50 Series
Single output
Special Features
• Industry standard footprint
• Input voltage to ETS300-132-2
• Adjustable output voltage
• No minimum load required
• Separate case ground pin
• 2:1 input range for battery
• Undervoltage lockout (UVLO)
• UL, VDE and CSA
• Available RoHS compliant
• 2 year warranty
Safety
VDE0805/EN60950/IEC950
File No. 10401-3336-0205
Licence No. 40012035
UL60950 File No. E136005
CSA C22.2 No. 950
File No. LR41062C
Total Power:
Input Voltage: 18 - 36VDC
# of Outputs:
MTBF >1.4 million hours
(Bellcore 332)
powered applications
safety approvals
33 - 50W
36 - 75VDC
Single
The BXB50 Series are high power density dc-dc converters
packaged in the industry standard footprint (2.40 x 2.28 x 0.50
inches) to give designers optimum choices when specifying for
both new and replacement designs. Suitable for a wide range of
applications in nearly any industry, the BXB50 was particularly
designed with communication and distributed power applications
in mind. Using Bellcore 332, the MTBF is greater than 1,400,000
hours. Aluminum baseplate technology with four threaded M3
inserts makes heatsink attachment and optimum thermal
management easy. The BXB50 series are approved to IEC950 by
UL, CSA and VDE.
Embedded Power for
Business-Critical Continuity
Rev.03.08.07
bxb50s
1 of 4

Related parts for bxb50s

bxb50s Summary of contents

Page 1

... Using Bellcore 332, the MTBF is greater than 1,400,000 hours. Aluminum baseplate technology with four threaded M3 inserts makes heatsink attachment and optimum thermal management easy. The BXB50 series are approved to IEC950 by UL, CSA and VDE. Embedded Power for Business-Critical Continuity Rev.03.08.07 bxb50s ...

Page 2

... Aluminum baseplate with plastic case UL94V-0 110 g (3.88 oz) Bellcore 332 1,400,000 hours MIL-HDBK-217F 580,000 hours @ 40 °C, 100% load min. Operating case temp. -40 °C to +100 °C Non-operating -55 °C to +125 °C Operating 10,000 feet max. Non-operating 40,000 feet max. 5-500 Hz 2.4 G rms (approx.) Rev.03.08.07 bxb50s ...

Page 3

... LINE LOAD 76% ±0.05% ±0.10% BXB50-24S3V3FLTJ 83% ±0.05% ±0.10% BXB50-24S12FLTJ 83% ±0.05% ±0.10% BXB50-24S15FLTJ 77% ±0.05% ±0.10% BXB50-48S3V3FLTJ 82% ±0.05% ±0.10% BXB50-48S05FLTJ 84% ±0.05% ±0.10% BXB50-48S12FLTJ Continuous, automatic recovery Non-latching Non-latching 110 °C baseplate, automatic recovery ETS300-132-2 8 TRIM UP RT1 7 OR RT2 TRIM DOWN 6 Rev.03.08.07 bxb50s (7,9,10) ...

Page 4

... Connectivity DC Power Embedded Power Inbound Power Integrated Cabinet Solutions Outside Plant Precision Cooling Site Monitoring and Services EmersonNetworkPower. com Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2007 Emerson Electric Co. Rev.03.08.07 bxb50s ...