S30 ETC2 [List of Unclassifed Manufacturers], S30 Datasheet

no-image

S30

Manufacturer Part Number
S30
Description
Sensors - ac-Voltage
Manufacturer
ETC2 [List of Unclassifed Manufacturers]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
S30-A150X
Manufacturer:
EPCOS
Quantity:
5 591
Part Number:
S30-A200X
Manufacturer:
TDK/东电化
Quantity:
20 000
Part Number:
S30-A300X
Manufacturer:
EPCOS
Quantity:
5 114
Part Number:
S30-A300XS
Manufacturer:
TDK/东电化
Quantity:
20 000
Part Number:
S30-A400X
Manufacturer:
EPCOS
Quantity:
12 541
Part Number:
S30-A500XS
Manufacturer:
SUMIDA
Quantity:
46
Part Number:
S30-A90X
Manufacturer:
HJ
Quantity:
4 500
Part Number:
S30-A90X
Manufacturer:
TDK/东电化
Quantity:
20 000
Part Number:
S300-04A
Manufacturer:
AD
Quantity:
9
Part Number:
S30011
Manufacturer:
AUK
Quantity:
20 000
* Standard 2 m (6.5') cable models are listed.
Printed in USA
• 9 m (30') cable: add suffix “W/30” (e.g., S303E W/30).
• 4-pin Micro-style QD models: add suffix “Q1” (e.g., S303EQ1). A model with a QD connector requires a mating cable.
P
WARNING . . .
Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death.
These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety
applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition.
Consult your current Banner Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for
personnel protection.
Sensing Mode
Opposed
Polarized
Retroreflective
Fixed-Field
Not To Be Used for Personnel Protection
S30 Sensors – ac-Voltage Series
Self-contained ac-operated sensors
• Featuring EZ-BEAM
• 30 mm plastic threaded barrel sensor in opposed, retroreflective or fixed-field
• Completely epoxy-encapsulated to provide superior durability, even in harsh
• Innovative dual-indicator system takes the guesswork out of sensor performance
• 20 to 250V ac (3-wire hookup); SPST solid-state switch output, maximum
provide reliable sensing without the need for adjustments
modes
sensing environments rated to IP69K
monitoring
load 300 mA
60 m (200')
6 m (20')
200 mm (8") cutoff
400 mm (16") cutoff
600 mm (24") cutoff
Range
Models
01/05
®
technology, the specially designed optics and electronics
Visible Red
Infrared
Infrared
950 nm
680 nm
880 nm
LED
Features
Output
DO
DO
DO
DO
DO
LO
LO
LO
LO
LO
S303E
S30AW3R
S30RW3R
S30AW3LP
S30RW3LP
S30AW3FF200
S30RW3FF200
S30AW3FF400
S30RW3FF400
S30AW3FF600
S30RW3FF600
Model*
P/N 121519

Related parts for S30

S30 Summary of contents

Page 1

... Fixed-Field * Standard 2 m (6.5') cable models are listed. • (30') cable: add suffix “W/30” (e.g., S303E W/30). • 4-pin Micro-style QD models: add suffix “Q1” (e.g., S303EQ1). A model with a QD connector requires a mating cable. WARNING . . . Not To Be Used for Personnel Protection Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death. ...

Page 2

... Fixed-Field Sensing – Theory of Operation The S30FF compares the reflections of its emitted light beam (E) from an object back to the sensor’s two differently aimed detectors, R1 and R2 (see Figure 1). If the near detector (R1) light signal is stronger than the far detector (R2) light signal (see object A, closer than the cutoff distance), the sensor responds to the object ...

Page 3

... Banner Engineering Corp. Minneapolis, MN U.S.A. • www.bannerengineering.com • Tel: 763.544.3164 S30 Sensors – ac-Voltage Series Color Sensitivity The effects of object reflectivity on cutoff distance, though small, may be important for some applications expected that at any given cutoff setting, the actual cutoff distance for lower reflectance targets will be slightly shorter than for higher reflectance targets (see Figure-of-Merit information on page 5) ...

Page 4

... S30 Sensors – ac-Voltage Series Supply Voltage and 20 to 250V ac (50/60 Hz) Current Average current Peak current: 200 mA @ 20V ac, 500 mA @ 120V ac, 750 mA @ 250V ac Supply Protection Protected against transient voltages Circuitry Output Configuration SPST solid-state ac switch; three-wire hookup; light operate or dark operate, depending on model Light Operate: Output conducts when sensor sees its own (or the emitter’ ...

Page 5

... Actual sensing range may be more or less than specified, depending on the efficiency and reflective area of the retroreflector used. Banner Engineering Corp. Minneapolis, MN U.S.A. • www.bannerengineering.com • Tel: 763.544.3164 S30 Sensors – ac-Voltage Series Performance Curves Beam Pattern Performance based on use of a 90% reflectance white test card. 1000 S30 Series E 30" ...

Page 6

... S30 Sensors – ac-Voltage Series Cabled Models ���������� ���������������� ����������������� ...

Page 7

... S30 Sensors – ac-Voltage Series Style Model 4-pin MQAC-406 Micro-style MQAC-415 Straight MQAC-430 4-pin MQAC-406RA Micro-style MQAC-415RA Right-angle MQAC-430RA WARRANTY: Banner Engineering Corp. warrants its products to be free from defects for one year. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period ...

Related keywords