hw1b-m501y IDEC Corporation, hw1b-m501y Datasheet - Page 43

no-image

hw1b-m501y

Manufacturer Part Number
hw1b-m501y
Description
Complete With Ip20 ?nger-safe Contact Blocks Ensure Safety And Save Wiring Time
Manufacturer
IDEC Corporation
Datasheet
Replacement of Lamps
Lamps can be replaced by using the lamp holder tool (OR-
55) from the front of the panel, or by removing the contact
block from the operator unit.
• Removing the Lamps from the Front of the Panel
[How to Remove]
1. To remove, slip the lamp holder tool onto the lamp head
[How to Install]
1. To install, insert the lamp head into the lamp holder tool,
2. Place the pins on the lamp base to the grooves in the
Nameplate
When anti-rotation is not required, remove the projection
from the nameplate using pliers.
46
ø22
Instructions
lightly. Then push slightly, and turn the lamp holder tool
counterclockwise.
and hold the lamp as shown in the figure below.
lamp socket. Insert the lamp and turn it clockwise.
HW
Lamp
Series
Lamp Holder Tool
Instructions
Projection
Nameplate
Grooves in the
Operator Unit
Close Mounting
When mounting the units closely in a horizontal row on
30mm centers, use optional barriers to prevent interconnec-
tion between adjoining terminals. The barriers can be
attached simply by pressing them onto the sides of contact
blocks.
When mounting transformer type illuminated units closely in
a horizontal row on 30mm centers, insert solid wires or
stranded wires into inside of the terminal screw on the trans-
former (see figure below) to prevent short circuit between
adjoining terminals.
When using transformer type pilot lights closely mounted in
horizontal and vertical rows on 30mm centers, keep the
ambient temperature below 40°C.
X1
Barrier
30
Inside
X2
X1
Inside
30
X2

Related parts for hw1b-m501y