zl30100 Zarlink Semiconductor, zl30100 Datasheet - Page 10

no-image

zl30100

Manufacturer Part Number
zl30100
Description
T1/e1 System Synchronizer
Manufacturer
Zarlink Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
zl30100QD
Manufacturer:
ZARILNK
Quantity:
20 000
Part Number:
zl30100QDC
Manufacturer:
MAXIM
Quantity:
4
Part Number:
zl30100QDC1
Manufacturer:
ZARLINK
Quantity:
101
Part Number:
zl30100QDG1
Manufacturer:
ZARLINK
Quantity:
20 000
Pin Description (continued)
3.0
The ZL30100 is a DS1/E1 System Synchronizer providing timing (clock) and synchronization (frame) signals to
interface circuits for DS1 and E1 Primary Rate Digital Transmission links, see Table 1. Figure 1 is a functional block
diagram which is described in the following sections.
3.1
The ZL30100 accepts two simultaneous reference input signals and operates on their rising edges. One of them,
the primary reference (REF0) or the secondary reference (REF1) signal can be selected as input to the TIE
corrector circuit based on the reference selection (REF_SEL) input.
3.2
The input references are monitored by two independent reference monitor blocks, one for each reference. The
block diagram of a single reference monitor is shown in Figure 3. For each reference clock, the frequency is
detected and the clock is continuously monitored for three independent criteria that indicate abnormal behavior of
the reference signal, for example; long term drift from its nominal frequency or excessive jitter. To ensure proper
operation of the reference monitor circuit, the minimum input pulse width restriction of 15 nsec must be
observed.
Pin #
59
60
61
62
63
64
Reference Frequency Detector: This detector determines whether the frequency of the reference clock is
8 kHz, 1.544 MHz, 2.048 MHz, 8.192 MHz or 16.384 MHz and provides this information to the various
monitor circuits and the phase detector circuit of the DPLL.
Precise Frequency Monitor: This circuit determines whether the frequency of the reference clock is within
the applicable out-of-range limits selected by the OOR_SEL pin, see Figure 5, Figure 6 and Table 1. It will
take the precise frequency monitor up to 10 s to qualify or disqualify the input reference.
Coarse Frequency Monitor (CFM): This circuit monitors the reference frequency over intervals of
approximately 30 Ps to quickly detect large frequency changes.
Single Cycle Monitor (SCM): This detector checks the period of a single clock cycle to detect large phase
hits or the complete loss of the clock.
Reference Select Multiplexer (MUX)
Reference Monitor
Functional Description
OOR_SEL
TIE_CLR
BW_SEL
Name
V
NC
IC
DD
Internal Connection. Connect this pin to ground.
Out Of Range Selection (Input). This pin selects the out of range reference rejection
limits, see Table 1 on page 16.
Positive Supply Voltage. +3.3 V
No internal bonding Connection. Leave unconnected.
TIE Corrector Circuit Reset (Input). A logic low at this input resets the Time Interval
Error (TIE) correction circuit resulting in a realignment of the input phase with the output
phase.
Filter Bandwidth Selection (Input). This pin selects the bandwidth of the DPLL loop
filter, see Table 2 on page 17. Set continuously high to track jitter on the input reference
closely or set temporarily high to allow the ZL30100 to quickly lock to the input reference.
Zarlink Semiconductor Inc.
ZL30100
10
DC
nominal.
Description
Data Sheet

Related parts for zl30100