ml2216 Oki Semiconductor, ml2216 Datasheet - Page 36

no-image

ml2216

Manufacturer Part Number
ml2216
Description
Oki Adpcm2 Algorithm-based Speech Synthesis Lsi
Manufacturer
Oki Semiconductor
Datasheet
10. VOL Command
VOL command is used to adjust the volume. It is possible to input the VOL command regardless of the status of the
NCR of that is playing back, but the prescribed command interval is required.
Note that VOL command input during power down, shifting to power up, and shifting to power down will be
ignored.
The volume can be set in 16 steps. The initial value after reset release is set to 0dB. The setting value of the VOL
command is held at the time of power down and STOP command input.
Following are the volume settings (V3 to V0):
OKI Semiconductor
• command
1
0
V3
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
V2
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
V3
V1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
V2
V0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
V1
–10.45 dB
–12.76 dB
–15.92 dB
–20.90 dB
–33.98 dB
–0.63 dB
–1.31 dB
–2.05 dB
–2.85 dB
–3.74 dB
–4.73 dB
–5.85 dB
–7.13 dB
–8.64 dB
V0
Volume
0 dB
OFF
ML2216/ML22P16
FEDL2216FULL-03
36/48

Related parts for ml2216