s-8232nxft-t2-g Seiko Instruments Inc., s-8232nxft-t2-g Datasheet - Page 9

no-image

s-8232nxft-t2-g

Manufacturer Part Number
s-8232nxft-t2-g
Description
Battery Protection Ic For 2-serial-cell Pack S-8232 Series
Manufacturer
Seiko Instruments Inc.
Datasheet
*1. Since products are not screened at high and low temperature, the specification for this temperature range is
*2. Auxiliary overcharge detection voltage is equal to the overcharge detection voltage times 1.11 for the
*3. Temperature coefficient 1 for detection voltage should be applied to overcharge detection voltage,
*4. Temperature coefficient 2 for detection voltage should be applied to overcurrent detection voltage.
*5. The DO pin and CO pin logic are established at the operating voltage.
DETECTION VOLTAGE
Overcharge detection voltage 1, 2
Auxiliary overcharge detection voltage 1, 2
V
V
Overcharge release voltage 1, 2
Overdischarge detection voltage 1, 2
Overdischarge release voltage 1, 2
Overcurrent detection voltage 1
Overcurrent detection voltage 2
Temperature coefficient 1 for detection voltage
Temperature coefficient 2 for detection voltage
DELAY TIME (C3 = 0.22 µF)
Overcharge detection delay time 1, 2
Overdischarge detection delay time 1, 2
Overcurrent detection delay time 1
INPUT VOLTAGE
Input voltage between VCC and VSS
OPERATING VOLTAGE
Operating voltage between VCC and VSS
CURRENT CONSUMPTION
Current consumption during normal operation
Current consumption at power down
OUTPUT VOLTAGE
DO voltage “H”
DO voltage “L”
CO voltage “H”
CO PIN INTERNAL RESISTANCE
Resistance between VSS and CO
INTERNAL RESISTANCE
Resistance between VCC and VM
Resistance between VSS and VM
0 V BATTERY CHARGE FUNCTION
0 V battery charge starting charger voltage
0 V battery charge inhibition battery voltage 1, 2 V
Rev.5.7
CUaux1
CUaux1
guaranteed by design, not tested in production.
products without overcharge hysteresis, and times 1.25 for other products.
overcharge release voltage, overdischarge detection voltage, and overdischarge release voltage.
, V
, V
CUaux2
CUaux2
_00
= V
= V
CU1
CU1
, V
, V
Item
CU2
CU2
× 1.25 or
× 1.11
*5
*2
*3
*4
BATTERY PROTECTION IC FOR 2-SERIAL-CELL PACK
V
V
V
V
V
V
V
V
T
T
t
t
t
V
V
I
I
V
V
V
R
R
R
V
Symbol
CU1, 2
DD1, 2
IOV1
OPE
PDN
COE1
COE2
CU1, 2
CUaux1, 2
CUaux1, 2
CD1, 2
DD1, 2
DU1, 2
IOV1
IOV2
DS
DSOP
DO(H)
DO(L)
CO(H)
0CHA
0INH1, 2
COL
VCM
VSM
Seiko Instruments Inc.
Ta = − 40°C to + 85°C
Ta = − 40°C to + 85°C
function “unavailable”
0 V battery charging
0 V battery charging
Absolute maximum
function “available”
Table 7
Load short circuit,
Output logic fixed
V
V
V
3.85 V to 4.60 V,
3.60 V to 4.60 V,
1.70 V to 2.60 V,
1.70 V to 3.80 V,
0.07 V to 0.30 V,
V1 = V2 = 3.6 V
V1 = V2 = 1.5 V
CO
CC
VM
V
V
V
I
I
I
CC
OUT
OUT
OUT
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Condition
CU1, 2
CU1, 2
− V
− V
− V
0.01 s
rating
reference
1.0 s
0.1 s
= 10 µA
= 10 µA
= 10 µA
VM
SS
SS
× 1.25
× 1.11
(Ta = − 40°C to +85°C unless otherwise specified
= 1.1 V
= 9.4 V
= 0.5 V
*1
*1
− 0.055
− 0.080
− 0.110
− 0.130
− 0.033
V
V
× 1.19
V
× 1.05
V
V
V
− 1.70 − 1.20
− 0.24 − 0.05
− 0.17
− 0.27
V
− 0.6
− 0.3
Min.
0.55
0.22
0.26
0.20
V
V
387
V
CU1, 2
CU1, 2
CU1, 2
CD1, 2
DD1, 2
DU1, 2
6.3
2.0
1.8
67
79
IOV1
0
CC
CC
SS
− 0.003
+ 0.003
− 0.019
0.0002
× 1.25
× 1.11
V
V
V
V
V
V
V
Typ.
1.00
0.75
0.88
100
240
597
V
V
V
7.5
0.6
CU1, 2
CU1, 2
CU1, 2
CD1, 2
DD1, 2
DU1, 2
10
IOV1
0
CC
SS
CC
+ 0.045
+ 0.070
+ 0.100
+ 0.120
+ 0.033
× 1.31
× 1.17
− 0.71
+ 0.17
V
V
V
V
V
V
Max.
1491
V
2.06
14.7
14.2
0.10
2.20
1.25
1.57
141
878
V
V
V
0.6
CU1, 2
CU1, 2
CU1, 2
CD1, 2
DD1 ,2
DU1, 2
18
16
IOV1
0
CC
SS
CC
mV/°C
mV/°C
S-8232 Series
Unit
MΩ
ms
ms
µA
µA
kΩ
kΩ
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
s
Condition
12, 13
Test
1, 2
1, 2
1, 2
1, 2
1, 2
1, 2
8, 9
8, 9
10
11
3
3
4
4
6
6
7
7
5
5
Circuit
Test
1
1
1
1
1
1
1
1
5
5
5
2
2
3
3
4
4
2
2
6
6
*1
)
9