mlx90323 Melexis Company, mlx90323 Datasheet - Page 20

no-image

mlx90323

Manufacturer Part Number
mlx90323
Description
4 ? 20 Ma Loop Sensor Interface With Signal Conditioning And Eeprom
Manufacturer
Melexis Company
Datasheet
Note: Because of space considerations, the measured temperature can’t be kept in the RAM at all times. If
the measured temperature is to be available, the temperature filter variable, N_Factor, must be set to 6.
3901090323
Rev 001
43-44
46-47
51-52
54-55
56-57
58-59
60-61
62-63
45
48
49
50
53
Coms_backup
Tempo1
Tempo2
Signal_In
P3_copy
Adsav1
Aaccsav
Baccsav
DAC_gain
DAC_offset
Temp_f
Signal_Out
Adsav2
Address saved when command is send.
Measured temperature, internal or external, and temporary
variable 1.
Temporary variable 2.
Digitized signal value, analog and digital mode
Port 3 setting copy.
Address saved at interrupt.
A-Accumulators saved at interrupt.
B-Accumulators saved at interrupt.
DAC gain (GN).
DAC offset (OF).
Filtered temperature. This is a 10 bit number that is left
justified in a 16 bit field.
Digitized linearity corrected signal value. Digital mode only.
Address saved when call.
Page 20 of 24
with Signal Conditioning and EEPROM
4 – 20 mA Loop Sensor Interface
MLX90323
Data Sheet
March/08