mlx90316 Melexis Company, mlx90316 Datasheet - Page 21

no-image

mlx90316

Manufacturer Part Number
mlx90316
Description
Rotary Position Sensor Ic
Manufacturer
Melexis Company
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
mlx90316-LDC-BDG
Manufacturer:
MELEXIS
Quantity:
3 550
Part Number:
mlx90316-LDC-BDG-SPI
Manufacturer:
MELEXIS
Quantity:
3 550
Part Number:
mlx90316BAC
Manufacturer:
MELEXIS
Quantity:
5 305
Part Number:
mlx90316DKC-BCG
Manufacturer:
MELEXIS/迈来芯
Quantity:
20 000
Part Number:
mlx90316EDC-BCG-000-RE
Manufacturer:
INFINEON
Quantity:
101
Part Number:
mlx90316EDC-BCG-000-RE
Manufacturer:
MELEXIS/迈来芯
Quantity:
20 000
Part Number:
mlx90316KDC
Manufacturer:
MELEXIS/迈来芯
Quantity:
20 000
Part Number:
mlx90316KDC-BCG
Manufacturer:
MELEXIS/迈来芯
Quantity:
20 000
Part Number:
mlx90316KDC-BCG-000-RE
Manufacturer:
MAXIM
Quantity:
1 400
Part Number:
mlx90316KDC-BCG-000-RE
Manufacturer:
MELEXIS/迈来芯
Quantity:
20 000
Part Number:
mlx90316KDC-BCG-000-RE
0
14.4.3. RGThresL, RGThresH Parameters
RGThresL & RGThresH define the boundaries within the gain setting (Rough Gain) is allowed to vary.
Outside this range, the output is set in diagnostic low.
14.5. FILTER
The MLX90316 includes 3 types of filters:
Note: if the parameter FSWAP is set to “1”, the filtering is active on the digital angle. If set to “0”, the
filtering is active on the output transfer function.
14.5.1. Hysteresis Filter
The FHYST parameter is a hysteresis filter. The output value of the IC is not updated when the digital step
is smaller than the programmed FHYST parameter value. The output value is modified when the
increment is bigger than the hysteresis. The hysteresis filter reduces therefore the resolution to a level
compatible with the internal noise of the IC. The hysteresis must be programmed to a value close to the
noise level.
Please note that for the programmable version, the FHYST parameter is set to 4 by default. If you do not
wish this feature, please set it to “0”.
14.5.2. FIR Filters
The MLX90316 features 6 FIR filter modes controlled with Filter = 0…5. The transfer function is described
below:
3901090316
Rev. 003
Hysteresis Filter: programmable by the FHYST parameter
Low Pass FIR Filters controlled with the Filter parameter
Low Pass IIR Filter controlled with the Filter parameter and the coefficients FILTER A1 and
FILTER A2
Parameter
FSWAP
FILTER
FHYST
y
n
=
i
=
Page 21 of 41
j
0
1
0 … 11 ; step 0.04
a
i
i
=
j
0
Value
0… 6
a
i
0
1
x
n
i
Rotary Position Sensor IC
Unit
deg
MLX90316
Data Sheet
April 07

Related parts for mlx90316