pcf8579h-1 NXP Semiconductors, pcf8579h-1 Datasheet - Page 21

no-image

pcf8579h-1

Manufacturer Part Number
pcf8579h-1
Description
Lcd Column Driver For Dot Matrix Graphic Displays
Manufacturer
NXP Semiconductors
Datasheet
Philips Semiconductors
9
The I
between different ICs or modules. The two lines are a
serial data line (SDA) and a serial clock line (SCL) which
must be connected to a positive supply via a pull-up
resistor. Data transfer may be initiated only when the bus
is not busy.
9.1
One data bit is transferred during each clock pulse.
The data on the SDA line must remain stable during the
HIGH period of the clock pulse as changes in the data line
at this moment will be interpreted as control signals.
9.2
Both data and clock lines remain HIGH when the bus is not
busy. A HIGH-to-LOW transition of the data line, while the
clock is HIGH, is defined as the start condition (S).
A LOW-to-HIGH transition of the data line while the clock
is HIGH, is defined as the stop condition (P).
9.3
A device transmitting a message is a ‘transmitter’, a device
receiving a message is the ‘receiver’. The device that
controls the message flow is the ‘master’ and the devices
which are controlled by the master are the ‘slaves’.
2003 Sep 01
LCD column driver for dot matrix graphic
displays
CHARACTERISTICS OF THE I
2
C-bus is for bidirectional, two-line communication
Bit transfer
Start and stop conditions
System configuration
SDA
SCL
2
C-BUS
data valid
data line
stable;
Fig.13 Bit transfer.
21
9.4
The number of data bytes transferred between the start
and stop conditions from transmitter to receiver is
unlimited. Each data byte of eight bits is followed by one
acknowledge bit. The acknowledge bit is a HIGH level put
on the bus by the transmitter, whereas the master
generates an extra acknowledge related clock pulse.
A slave receiver which is addressed must generate an
acknowledge after the reception of each byte. Also a
master must generate an acknowledge after the reception
of each byte that has been clocked out of the slave
transmitter. The device that acknowledges must pull down
the SDA line during the acknowledge clock pulse, so that
the SDA line is stable LOW during the HIGH period of the
acknowledge related clock pulse (set-up and hold times
must be taken into consideration). A master receiver must
signal the end of a data transmission to the transmitter by
not generating an acknowledge on the last byte that has
been clocked out of the slave. In this event the transmitter
must leave the data line HIGH to enable the master to
generate a stop condition.
change
allowed
of data
Acknowledge
MBA607
Product specification
PCF8579

Related parts for pcf8579h-1