Contact data
Number and type of contacts
Contact material
Max. switching voltage
Min. switching voltage
Rated load
Min. switching current
Max. inrush current
Rated current
Max. breaking capacity
Min. breaking capacity
Contact resistance
Max. operating frequency
• at rated load
• no load
Coil data
Rated voltage
Must release voltage
Operating range of supply voltage
Rated power consumption
Insulation
Insulation category
Insulation rated voltage
Rated surge voltage
Overvoltage category
Insulation pollution degree
Dielectric strength
Contact - coil distance
• clearance / • creepage
General data
Operating time (typical value)
Release time (typical value)
Electrical life
Mechanical life (cycles)
Motor load - according to the UL 508
Dimensions (L x W x H)
Weight
Ambient temperature
Cover protection category
Environmental protection
Shock resistance
Vibration resistance
Solder bath temperature
Soldering time
R15 2 C/O
R15 3 C/O
Export Sales Department Phone +48 68 47 90 832 • Marketing Department Phone +48 68 47 90 900
• between coil and contacts
• contact clearance
• pole - pole
R15
industrial relays of small dimensions
• storage
• resistive AC1
• cos φ
• operating
R15 4 C/O
AC/DC
AC1
DC1
AC1
AC1
DC
AC
• General purpose relays • For plug-in sockets, 35 mm DIN rail mount, EN 50022
or on panel mounting • Cadmium - free contacts - R15 2 C/O, R15 3 C/O relays
• WT (mechanical indicator + lockable front test button) - standard features
of R15 2 C/O, R15 3 C/O relays in cover, for plug-in sockets. Relays may be provided
with the test buttons type P (no latching) and plugs - page 199 • Have obtained
LR Type Approval Certificate (Lloyd's Register) - R15...WT 2 C/O, R15...WT 3 C/O
• Recognitions, certifications, directives: RoHS,
2 C/O, 3 C/O, 4 C/O
2 C/O, 3 C/O:
4 C/O:
250 V / 250 V
2 C/O, 3 C/O:
4 C/O:
10 A / 250 V AC
10 A / 24 V DC
2 C/O, 3 C/O:
4 C/O:
20 A
10 A
2 500 VA
2 C/O, 3 C/O:
4 C/O:
≤ 100 mΩ
1 200 cycles/hour
12 000 cycles/hour
2 C/O, 3 C/O:
6...220 V
AC:
see Tables 1, 2, 3, 4
AC:
2 C/O, 3 C/O:
250 V AC
2 500 V AC
III
3
2 500 V AC
1 500 V AC
2 000 V AC
2 C/O, 3 C/O, 4 C/O:
AC:
AC:
≥ 2 x 10
see Fig. 2
≥ 2 x 10
2 C/O:
3 C/O:
3 C/O:
2 C/O, 3 C/O:
2 C/O, 3 C/O:
-40...+85
AC:
IP 40
RTI
10 g
5 g
max. 270
max. 5 s
≥ 0,15 U
2,8 VA
12 ms
10 ms
-40...+55
10...150 Hz
AgCdO, AgCdO/Au 0,2 µm, AgCdO/Au 5 µm
10 V
10 mA
0,5 W
1/3 HP
1/3 HP
1/2 HP
PN-EN 60664-1
PN-EN 116000-3
7
5
o
o
C
50 Hz
C
AgCdO,
10 A, 250 V AC
AgNi, AgNi/Au 0,2 µm, AgNi/Au 5 µm
5 V
5 mA
0,3 W
6...240 V
C250
35 x 35 x 54,4 mm
83 g
n
AgCdO,
o
AgCdO,
120 V AC, single-phase motor
120 V AC, single-phase motor
240 V AC, three-phase motor
C
AgNi,
2,5 VA
≥ 3 mm /
AgNi,
AgNi,
10 V
0,5 W
50/60 Hz
10 mA
5 V
5 mA
0,3 W
60 Hz
AgCdO/Au 0,2 µm,
AgNi/Au 0,2 µm,
AgCdO/Au 0,2 µm,
AgCdO/Au 0,2 µm,
2 C/O, 3 C/O:
AgNi/Au 0,2 µm,
AgNi/Au 0,2 µm,
4 C/O:
DC:
DC:
4 C/O:
DC:
DC:
4 C/O:
4 C/O:
DC:
≥ 0,1 U
1,5 W
18 ms
7 ms
-40...+70
6...240 V
B250
35 x 42,5 x 54,5 mm
95 g
≥ 4,2 mm,
5 V
1/2 HP
1/2 HP
5 V
0,05 W
2 mA
2 mA
n
AgNi/Au 5 µm
0,05 W
AgCdO/Au 5 µm
o
C
50 Hz, 60 Hz
240 V AC, single-phase motor
240 V AC, single-phase motor
AgNi/Au 5 µm
AgCdO/Au 5 µm
4 C/O:
AgCdO/Au 5 µm
AgNi/Au 5 µm
≥ 3,2 mm
www.relpol.com.pl
127

Related parts for r15-2012-23-5006-wtlv

r15-2012-23-5006-wtlv Summary of contents

Page 1

... Export Sales Department Phone + 832 • Marketing Department Phone + 900 • General purpose relays • For plug-in sockets DIN rail mount, EN 50022 or on panel mounting • Cadmium - free contacts - R15 2 C/O, R15 3 C/O relays • WT (mechanical indicator + lockable front test button) - standard features of R15 2 C/O, R15 3 C/O relays in cover, for plug-in sockets. Relays may be provided with the test buttons type P (no latching) and plugs - page 199 • ...

Page 2

... R15 industrial relays of small dimensions 128 The data in bold type pertain to the standard versions of the relays. The data in bold type pertain to the standard versions of the relays. www.relpol.com.pl Export Sales Department Phone + 832 • Marketing Department Phone + 900 ...

Page 3

... GOP11 with clip R159 1051 and spring clamp R15 5922 • direct PCB mounting. Relays R15 4 C/O are designed for: • screw terminals plug-in sockets GZ14U with clip GZ14 0737 DIN rail mount, EN 50022; GZ14 with clip GZ14 0737, on panel mounting • ...

Page 4

... Export Sales Department Phone + 832 • Marketing Department Phone + 900 • WT (mechanical indicator + lockable front test button) - standard features of R15 2 C/O, R15 3 C/O relays in cover, for plug-in sockets. Relays may be provided with the test buttons type P (no latching) and plugs - page 199 • ...

Page 5

... R15, contact material AgNi, with two changeover contacts, in cover IP 40, for plug-in sockets, voltage version 24 V DC, with mechanical indicator and lockable front test button R15-2013-23-5230-WTL relay R15, contact material AgNi, with three changeover contacts, in cover IP 40, for plug-in sockets, voltage version 230 V AC 50/60 Hz, with mechanical indicator and lockable front test button and light indicator (LED diode) Export Sales Department Phone + 832 • ...

Page 6

... KLD - test button without block function + light indicator (LED diode) + surge suppresion element (diode) D, KD, LD, KLD - only for DC coils Note: for R15 4 C/O relays 50/60 Hz coils are not offered, show coil according with Table pages 128, 129. Example of ordering code: R15-1014-23-3230-K ...

Related keywords