dsdx030g2r Sensortechnics GmbH, dsdx030g2r Datasheet

no-image

dsdx030g2r

Manufacturer Part Number
dsdx030g2r
Description
Digital Pressure Transducers
Manufacturer
Sensortechnics GmbH
Datasheet
FEATURES
APPLICATIONS
ELECTRICAL CONNECTION
February 2009 / 545
· 0...1 to 0...100 psi,
· Absolute, gage or
· Digital readout via I
· Precision ASIC conditioning
· Temperature compensated
· Non-ratiometric output
· Medical instrumentation
· Barometry
· HVAC controls
· Pneumatic controls
0...±1 to 0...±100 psi
differential pressure
N/C
DSDX
6
8 4
N/C
3
1
5
7
2
2
C-bus
GND
SDA
SCL
+Vs
IC
15 nF
220 nF
GENERAL DESCRIPTION
The DSDX series offers a digital
interface on a very cost-effective basis.
This family is fully calibrated and
temperature compen-sated using an
on-board ASIC. These sensors are
intended for use with non-corrosive,
non-ionic working fluids such as air
and dry gases.
Devices are available to measure
absolute, differential, and gage
pressures from 1 to 100 psi. The
absolute devices have an internal
vacuum reference and an output
signal proportional to absolute
pressure. Differential devices allow
application of pressure to either side
of the sensing diaphragm and can be
used
measurements.
for
gage
Note:
or
differential
A capacitor of 220 nF is required
between +Vs and GND.
Pin 2 is an internal device connection and
should be connected to ground with a
15 nF capacitor.
It is important to place the capacitors as
close to the pins as possible!
Pins 4, 6 and 8 are internal device
connections and should not be
connected for any reason!
Digital pressure transducers
All DSDX devices are accurate to with-
in ±2.0 %FSS for all gage and
absolute devices. The devices are
characterized for operation from a
single 5 V supply. The sensor is de-
signed and manufactured according
to standards laid down in ISO 9001.
www.sensortechnics.com
DSDX Series
1/8

Related parts for dsdx030g2r

dsdx030g2r Summary of contents

Page 1

FEATURES · 0...1 to 0...100 psi, 0...±1 to 0...±100 psi · Absolute, gage or differential pressure · Digital readout via I 2 C-bus · Precision ASIC conditioning · Temperature compensated · Non-ratiometric output APPLICATIONS · Medical instrumentation · Barometry · ...

Page 2

PRESSURE SENSOR CHARACTERISTICS Maximum ratings Supply voltage V 4. Lead temperature ( sec.) Caution! The sensor is not reverse polarity protected. Incorrect applications of excitation voltage or ground to the wrong pin can cause ...

Page 3

PERFORMANCE CHARACTERISTICS The output signal is not ratiometric to the supply voltage (V All DSDX... ...

Page 4

TOTAL ACCURACY (-20 TO +105°C) 3.0 2.0 1.0 0 -1.0 -2.0 -3.0 -20 0 Specification notes maximum burst pressure is exceeded, even momentarily, the package may leak or burst, or the pressure sensing die may fracture. 2. Span ...

Page 5

INTRODUCTION The DSDX is capable to generate a digital output signal. It runs a cyclic program, which will store a corrected 12-bit sensor value about every 10 ms within the output registers of the internal ASIC. In order to use ...

Page 6

INTERFACE PARAMETERS ...

Page 7

PHYSICAL DIMENSIONS D4 package 1.27 typ (0.050 typ) 7.87 typ (0.310 typ) 8.13 8.89 (0.320) (0.350) G2 package 1.27 typ (0.050 typ) 5.08 (0.200) A2 package 1.27 typ (0.050 typ) (0.315 typ) 8.89 (0.350) third angle projection February 2009 / ...

Page 8

ELECTRICAL CONNECTIONS DSDX...D4... +Vs SCL IC N/C GND SDA N/C N/C DSDX...A2R SCL +Vs N/C IC SDA GND N/C N/C ORDERING INFORMATION ...